ACE24C16A
Two-wire Serial EEPROM
DC Characteristics
Applicable over recommended operating range from: T
A
= -40℃ to +85℃, Vcc= +1.7V to +5.5V (unless otherwise noted).
Symbol
V
CC
I
CC1
I
CC2
I
SB1
I
SB2
I
LI
I
LO
V
IL1
V
IH1
V
OL2
V
OL1
Parameter
Supply Voltage
Supply Current
Supply Current
Standby Current
Standby Current
Input Leakage Current
Output Leakage Current
Input Low Level
Input High Level
Output Low Level 2
Output Low Level 1
Test Condition
Min
1.7
Typ
Max
5.5
Units
V
mA
mA
µA
µA
µA
µA
V
V
V
V
V
CC
= 5.5V, Read at 400K
V
CC
= 5.5V, Write at 400K
V
CC
= 1.7V, V
IN
= V
CC
/ V
SS
V
CC
= 5.5V, V
IN
= V
CC
/ V
SS
V
IN
= V
CC
/V
SS
V
OUT
= V
CC
/ V
SS
-0.6
V
CC
x0.7
V
CC
= 3.0V, I
OL
= 2.1 mA
V
CC
= 1.7V, I
OL
= 0.15 mA
0.4
2.0
1.0
3.0
1.0
6.0
0.10
0.05
3.0
3.0
V
CC
x0.3
V
CC
+0.5
0.4
0.2
Note: 1.
V
IL
min and
V
IH
max are reference only and are not tested.
VER 1.4