2 – Military ProASIC3/EL DC and Switching
Characteristics
General Specifications
Operating Conditions
Stresses beyond those listed in
may cause permanent damage to the device.
Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
absolute maximum ratings are stress ratings only; functional operation of the device at these or
any other conditions beyond those listed under the Recommended Operating Conditions specified
in
is not implied.
Table 2-1 •
Symbol
V
CC
V
JTAG
V
PUMP
V
CCPLL
V
CCI
Absolute Maximum Ratings
Parameter
DC core supply voltage
JTAG DC voltage
Programming voltage
Analog power supply (PLL)
DC I/O output buffer supply
voltage
for
A3PE600L
and
A3PE3000L. DC Output buffer
supply voltage for A3P1000.
I/O input voltage
Limits
–0.3 to 1.65
–0.3 to 3.75
–0.3 to 3.75
–0.3 to 1.65
–0.3 to 3.75
Units
V
V
V
V
V
VI
–0.3 V to 3.6 V (when I/O hot insertion mode is
enabled)
–0.3 V to (V
CCI
+ 1 V) or 3.6 V, whichever voltage
is lower (when I/O hot-insertion mode is
disabled)
V
VMV
T
STG 2
T
J 2
Notes:
DC input buffer supply voltage for
A3P1000
Storage temperature
Junction temperature
–0.3 to 3.75
–65 to +150
+150
V
°C
°C
1. The device should be operated within the limits specified by the datasheet. During transitions, the input
signal may undershoot or overshoot according to the limits shown in
2. For flash programming and retention maximum limits, refer to
and for
recommended operating limits, refer to
v1.0
2-1