REGISTER AND BIT DESCRIPTIONS CONT’D
OUTPUT
REG3
REG3
REG3
REG3
REG3
REG3
REG3
REG4
REG4
REG4
REG4
REG5
REG5
REG5
REG5
REG5
ADDRESS
0x30
0x30
0x32
0x32
0x32
0x32
0x32
0x40
0x41
0x41
0x41
0x50
0x50
0x51
0x51
0x51
BIT
[7:6]
[5:0]
[7]
[6:3]
[2]
[1]
[0]
[7:0]
[7]
[6:1]
[0]
[7:6]
[5:0]
[7]
[6:3]
[2]
NAME
-
VSET
ON
-
PHASE
nFLTMSK
OK
VSET
ON
-
OK
-
VSET
ON
-
DIS
ACCESS
R
R/W
R/W
R
R/W
R/W
R
R/W
R/W
R
R
R
R/W
R/W
R
R/W
Reserved.
Output Voltage Selection. See the
Output Voltage
Programming
section for more information.
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
Reserved.
Regulator Phase Control. Set bit to 1 for the regulator to
operate 180° out of phase with the oscillator, clear bit to 0 for
the regulator to operate in phase with the oscillator.
Regulator Fault Mask Control. Set bit to 1 enable fault-
interrupts, clear bit to 0 to disable fault-interrupts.
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
Output Voltage Selection. See the
Output Voltage
Programming
section for more information.
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
Reserved.
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
Reserved.
Output Voltage Selection. See the
Output Voltage
Programming
section for more information.
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
Reserved.
Output Discharge Control. When activated, LDO output is
discharged to GA through 1.5kΩ resistor when in shutdown.
Set bit to 1 to enable output voltage discharge in shutdown,
clear bit to 0 to disable this function.
Regulator Fault Mask Control. Set bit to 1 enable fault-
interrupts, clear bit to 0 to disable fault-interrupts.
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
Reserved.
Output Voltage Selection. See the
Output Voltage
Programming
section for more information.
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
Reserved.
Output Discharge Control. When activated, LDO output is
discharged to GA through 1.5kΩ resistor when in shutdown.
Set bit to 1 to enable output voltage discharge in shutdown,
clear bit to 0 to disable this function.
Regulator Fault Mask Control. Set bit to 1 enable fault-
interrupts, clear bit to 0 to disable fault-interrupts.
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
DESCRIPTION
REG5
REG5
REG6
REG6
REG6
REG6
REG6
0x51
0x51
0x60
0x60
0x61
0x61
0x61
[1]
[0]
[7:6]
[5:0]
[7]
[6:3]
[2]
nFLTMSK
OK
-
VSET
ON
-
DIS
R/W
R
R
R/W
R/W
R
R/W
REG6
REG6
0x61
0x61
[1]
[0]
nFLTMSK
OK
R/W
R
Innovative Power
TM
ActivePMU
TM
and
ActivePath
TM
are trademarks of Active-Semi.
I
2
C
TM
is a trademark of NXP.
- 12 -