(@ T = + 25°C, V = +15 V unless otherwise noted)
AD586–SPECIFICATIONS
A
IN
AD 586J
AD 586K/A
AD 586L/B
AD 586M
AD 586S
AD 586T
Model
Min Typ Max Min Typ Max Min Typ Max
Min Typ Max Min Typ Max Min Typ Max
Units
Output Voltage
4.980
5.020 4.995
25
5.005 4.9975
5.0025 4.998
5.002 4.990
2
5.010 4.9975
5.0025
10
V
Output Voltage Driftl
0°C to +70°C
15
5
ppm/°C
–55°C to +125°C
20
Gain Adjustment
+6
–2
+6
–2
+6
–2
+6
–2
+6
–2
+6
–2
%
Line Regulation1
10.8 V < +VIN < 36 V
T MIN to T MAX
11.4 V < +VIN < 36 V
T MIN to T MAX
100
100
100
100
±µV/V
µV/mA
150
150
Load Regulationl
Sourcing 0 < IOUT < 10 mA
25°C
100
100
100
100
100
100
100
100
150
150
150
150
T MIN to T MAX
Sinking –10 < IOUT < 0 mA
25°C
400
3
400
400
3
400
3
400
3
400
3
Quiescent Current
2
2
3
2
2
2
2
mA
Power Consumption
30
30
30
30
30
30
mW
Output Noise
0.1 Hz to 10 Hz
4
4
4
4
4
4
µV p-p
Spectral Density, 100 Hz
100
100
100
100
100
100
nV/√Hz
Long-T erm Stability
15
45
15
45
15
45
15
15
45
15
ppm/1000 Hr
mA
Short-Circuit Current-to-Ground
60
60
60
45 60
60
45 60
T emperature Range
Specified Performance2
0
+70
0
–40
+70
+85
+85
0
–40
–40
+70
+85
+85
0
+70 –55
+85 –55
+125 –55
+125 –55
+125 °C
+125
Operating Performance3
NOT ES
–40
+85 –40
–40
1Maximum output voltage drift is guaranteed for all packages and grades. Cerdip packaged parts are also 100°C production tested.
2Lower row shows specified performance for A and B grades.
3T he operating temperature range is defined as the temperatures extremes at which the device will still function. Parts may deviate from their specified performance outside their
specified temperature range.
Specifications subject to change without notice.
Specifications in boldface are rested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels. All min and max specifica-
tions are guaranteed, although only those shown in boldface are tested on all production units unless otherwise specified.
ABSO LUTE MAXIMUM RATINGS*
CO NNECTIO N D IAGRAM
(Top View)
VIN to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 V
Power Dissipation (25°C) . . . . . . . . . . . . . . . . . . . . . 500 mW
Storage T emperature . . . . . . . . . . . . . . . . . . –65°C to +150°C
Lead T emp (Soldering, 10 sec) . . . . . . . . . . . . . . . . . . +300°C
Package T hermal Resistance
θJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22°C/W
θJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110°C/W
Output Protection: Output safe for indefinite short to ground or
VIN
.
*Stresses above those listed under “Absolute Maximum Ratings” may cause
permanent damage to the device. T his is a stress rating only and functional
operation of the device at these or any other conditions above those indicated in the
operational section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
–2–
REV. C