AD7886  
Data read operations are controlled by the CS and RD inputs.  
These digital inputs, when low, enable the AD7886’s three-  
state output latches. Note, these latches cannot be enabled dur-  
ing conversion. In applications where CS and RD are tied per-  
manently low, as in Figure 11, the data bus will go into the  
three-state condition at the start of conversion and return to its  
active state when conversion is complete. Tying CS and RD  
permanently low is useful when external latches are used to  
store the conversion results. The data bus becomes active before  
BUSY returns high at the end of conversion, so that BUSY can  
be used as a clocking signal for the external latches.  
BIPOLAR OFFSET AND GAIN ADJUSTMENT  
In applications where absolute accuracy is important, offset and  
gain error can be adjusted to zero. Offset is adjusted by trim-  
ming the voltage at the VIN1 or VIN2 input when the analog in-  
put is at zero volts. This can be achieved by adjusting the offset  
of an external amplifier used to drive either of these inputs (see  
A1 in Figure 9). The trim procedure is as follows:  
Apply zero volts at AIN and adjust the offset of A1 until the  
ADC output code flickers between 0111 1111 1111 and 1000  
0000 0000.  
Gain error can be adjusted at either the first code transition  
(ADC negative full scale) or the last code transition (ADC posi-  
tive full scale). Adjusting the reference, as in Figure 9, will trim  
the positive gain error only. The trim procedure is as follows:  
A typical DSP application would have a timer connected to the  
CONVST input for precise sampling intervals. BUSY would be  
connected to the interrupt of a microprocessor that would be  
asserted at the end of every conversion. The microprocessor  
would then assert the CS and RD inputs and read the data from  
the ADC. For applications where both data reading and conver-  
sion control need to be managed by a microprocessor, a CONVST  
pulse can be decoded from the address bus. One decoding pos-  
sibility is that a write instruction to the ADC address starts a  
conversion, and a read instruction reads the conversion result.  
Apply a voltage of 4.99756 V, (FS/2–1 LSB) at AIN and  
adjust R3 until the output code flickers between 1111 1111  
1110 and 1111 11111111.  
If the first code transition needs adjusting, a gain trim must be  
included in the analog signal path. The trim procedure will then  
consist of applying an analog signal of –4.99756 V (–FS/2+1 LSB)  
and adjusting the trim until the output code flickers between  
0000 0000 0000 and 0000 0000 0001.  
TRACK-TO-HOLD  
TRANSITION  
+
5V  
t13  
AD845  
AIN  
t1  
+
A1  
V
DD  
t12  
t10  
CONVST  
CS  
CONVERSION  
START  
±
5V  
VIN1  
VIN2  
HOLD TO  
TRACK  
TRANSITION  
t2  
+V  
t3  
AGND  
t4  
RD  
+V  
IN  
+ 5V  
t5  
t11  
+
5REF  
V
OUT  
AD586  
GND  
tCONV  
R1  
82k  
BUSY  
DATA  
SUM  
t7  
AD707  
+
t6  
–3.5V  
R3  
5k  
DATA  
VALID  
V
REF  
HIGH IMPEDANCE  
AD7886*  
Figure 10. Conversion Start and Data Read Timing  
Diagram  
R2  
56k  
V
SS  
C2  
0.1µF  
C1  
10µF  
5V  
TRACK-TO-HOLD  
TRANSITION  
*ADDITIONAL PINS OMITTED FOR CLARITY  
t13  
Figure 9. Bipolar Operation with Gain Error Adjust  
t1  
CONVERSION  
START  
CONVST  
TIMING AND CONTROL  
t12  
Conversion start is controlled by the CONVST input (see Fig-  
ures 10 and 11). A high to low going edge on the CONVST in-  
put puts the track/hold amplifier into the hold mode. The ADC  
conversion procedure does not begin until a rising CONVST  
pulse edge occurs. The width of the CONVST pulse low time  
determines the track-to-hold settling time. The BUSY output,  
which indicates the status of the ADC, goes low while conver-  
sion is in progress. At the end of conversion BUSY returns high,  
indicating that new data is available on the AD7886’s output  
latches. The track/hold amplifier returns to the track mode at  
the end of conversion and remains there until the next  
CONVST pulse. Conversion starts must not be attempted while  
conversion is in progress as this will cause erroneous results.  
t5  
tCONV  
BUSY  
DATA  
HOLD TO TRACK  
TRANSITION  
t8  
t9  
HIGH IMPEDANCE  
DATA  
VALID  
Figure 11. Conversion Start and Data Read  
Timing Diagram, (CS = RD = 0 V)  
REV. B  
–8–