[AK4204]
OPERATION OVERVIEW
■
Charge Pump Circuit
Internal negative power supply circuit (Figure
3)
supplies the negative voltage to the video amp, and the video amp 0V
output is used for a pedestal level (Figure
4
and
Therefore, the output coupling capacitor can be removed.
AK4204
VDD1
Charge
Pump
Negative Power
CP
(+)
CN
1uF
VSS1
VEE
C2
(+)
10uF
C1
Figure 3. Charge Pump Circuit
Note 9. C1 and C2 should be low ESR (Equivalent Series Resistance) capacitors. When these capacitors are polarized,
the positive polarity pins should be connected to the CP or VSS1 pin.
AK4204
2 Vrms
0V
ROUT
(LOUT)
Figure 4. Audio Signal Output
AK4204
75Ω
VOUT
75Ω
0V
Figure 5. Video Signal Output
Rev. 0.1
-7-
2012/02