AS7C1025B
®
Recommended operating conditions
Parameter
Supply voltage
Input voltage
Ambient operating temperature
V
IL
min = -1.0V for pulse width less than 5ns
V
IH
max = V
CC
+2.0V for pulse width less than 5ns.
commercial
industrial
Symbol
V
CC
V
IH
V
IL
T
A
T
A
Min
4.5
2.2
–0.5
0
–40
Nominal
5.0
–
–
–
–
Max
5.5
V
CC
+ 0.5
0.8
70
85
Unit
V
V
V
o
o
C
C
DC operating characteristics (over the operating range)
1
-10
Parameter
Input leakage current
Output leakage
current
Operating power
supply current
Standby power supply
current
1
-12
1
1
110
50
–
–
–
–
1
1
100
45
–
–
–
–
-15
1
1
90
45
–
–
–
–
-20
1
1
80
40
µA
µA
mA
mA
Symbol
|
I
LI
|
|
I
LO
|
I
CC
I
SB
Test conditions
V
CC
= Max, V
IN
= GND to V
CC
V
CC
= Max, CE = V
IH
,
V
out
= GND to V
CC
V
CC
= Max
CE
≤
V
IL
, f = f
Max,
I
OUT
= 0 mA
V
CC
= Max
CE
≥
V
IH
, f = f
Max
V
CC
= Max
CE
≥
V
CC
–0.2 V,
V
IN
≤
0.2 V or V
IN
≥
V
CC
–0.2 V,
f=0
I
OL
= 8 mA, V
CC
= Min
I
OH
= –4 mA, V
CC
= Min
Min Max Min Max Min Max Min Max Unit
–
–
–
–
I
SB1
–
10
10
10
10
mA
Output voltage
V
OL
V
OH
–
2.4
0.4
–
2.4
0.4
–
–
2.4
0.4
–
–
2.4
0.4
–
V
V
Capacitance (
f = 1 MHz, T
a
= 25
o
C, V
CC
= NOMINAL
)
2
Parameter
Input capacitance
I/O capacitance
Symbol
C
IN
C
I/O
Signals
A, CE, WE, OE
I/O
Test conditions
V
IN
= 0 V
V
IN
= V
OUT
= 0 V
Max
5
7
Unit
pF
pF
3/26/04, v. 1.3
Alliance Semiconductor
P. 3 of 9