欢迎访问ic37.com |
会员登录 免费注册
发布采购

EP1S40B1508C6ES 参数 Datasheet PDF下载

EP1S40B1508C6ES图片预览
型号: EP1S40B1508C6ES
PDF下载: 下载PDF文件 查看货源
内容描述: Stratix器件系列数据手册 [Stratix Device Family Data Sheet]
分类和应用:
文件页数/大小: 290 页 / 3583 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号EP1S40B1508C6ES的Datasheet PDF文件第169页浏览型号EP1S40B1508C6ES的Datasheet PDF文件第170页浏览型号EP1S40B1508C6ES的Datasheet PDF文件第171页浏览型号EP1S40B1508C6ES的Datasheet PDF文件第172页浏览型号EP1S40B1508C6ES的Datasheet PDF文件第174页浏览型号EP1S40B1508C6ES的Datasheet PDF文件第175页浏览型号EP1S40B1508C6ES的Datasheet PDF文件第176页浏览型号EP1S40B1508C6ES的Datasheet PDF文件第177页  
Configuration & Testing  
While in the factory configuration, the factory-configuration logic  
performs the following operations:  
Loads a remote update-control register to determine the page  
address of the new application configuration  
Determines whether to enable a user watchdog timer for the  
application configuration  
Determines what the watchdog timer setting should be if it is  
enabled  
The user watchdog timer is a counter that must be continually reset  
within a specific amount of time in the user mode of an application  
configuration to ensure that valid configuration occurred during a remote  
update. Only valid application configurations designed for remote  
update can reset the user watchdog timer in user mode. If a valid  
application configuration does not reset the user watchdog timer in a  
specific amount of time, the timer updates a status register and loads the  
factory configuration. The user watchdog timer is automatically disabled  
for factory configurations.  
If an error occurs in loading the application configuration, the  
configuration logic writes a status register to specify the cause of the error.  
Once this occurs, the Stratix device automatically loads the factory  
configuration, which reads the status register and determines the reason  
for reconfiguration. Based on the reason, the factory configuration will  
take appropriate steps and will write the remote update control register  
to specify the next application configuration page to be loaded.  
When the Stratix device successfully loads the application configuration,  
it enters into user mode. The Stratix device then executes the main  
application of the user. Intellectual property (IP), such as a Nios® (16-bit  
ISA) and Nios® II (32-bit ISA) embedded processors, can help the Stratix  
device determine when remote update is coming. The Nios embedded  
processor or user logic receives incoming data, writes it to the  
configuration device, and loads the factory configuration. The factory  
configuration will read the remote update status register and determine  
the valid application configuration to load. Figure 3–2 shows the Stratix  
remote update. Figure 3–3 shows the transition diagram for remote  
update mode.  
Altera Corporation  
July 2005  
3–9  
Stratix Device Handbook, Volume 1