Engineering Data Sheet
Recommended Operating Conditions
The following table lists the recommended operating conditions.
Table 3. Recommended operating conditions at 25 C.
o
Power supply
Input clock pulses high level
1
Input clock pulse low level
1
Video charge output external bias
Clock frequency
Integration time
2
Parameters
Symbol
VDD
Vih
Vil
Vbias
Fclk
Tint
Min
4.5
VDD – 0.8
0.0
VDD – 0.5
Typical
5.0
VDD
0.0
VDD – 0.5
0.1
0.09 (128WSN)
0.18 (256WSN)
0.52 (512WSN)
Max
5.5
VDD
0.8
VDD
1.5 (128WSN)
1.5 (256WSN)
1.0 (512WSN)
9000
Units
Volts
Volts
Volts
Volts
MHz
ms
Notes:
1. Applies to all control-clock inputs.
2. Integration time is specified at room temperature such that the maximum dark current charge build up in each pixel is
less than 10% of the minimum saturation charge. Accordingly, it may be as long as 9 seconds at room temperature.
Longer integration times may be achieved by cooling the device. An appropriate clock frequency must be chosen so
that the shift register completes its operation within the desired integration time.