A43L3616
AC Operating Test Conditions
(VDD = 3.3V ±0.3V, TA = 0°C to +70°C )
Parameter
Value
AC input levels
VIH/VIL = 2.4V/0.4V
1.4V
Input timing measurement reference level
Input rise and all time (See note3)
Output timing measurement reference level
Output load condition
tr/tf = 1ns/1ns
1.4V
See Fig.2
3.3V
VOH(DC) = 2.4V, IOH = -2mA
VOL(DC) = 0.4V, IOL = 2mA
VTT =1.4V
50
1200
W
W
Output
ZO=50
W
OUTPUT
50pF
870
W
50pF
(Fig. 2) AC Output Load Circuit
(Fig. 1) DC Output Load Circuit
AC Characteristics
(AC operating conditions unless otherwise noted)
-6
-7
Symbol
Parameter
CAS Latency
Unit
Note
Min
Max
Min
Max
tCC
CLK cycle time
6
1000
7
1000
ns
1
tSAC
CLK to valid
Output delay
-
5
-
5.4
ns
1,2
3
tOH
tCH
Output data hold time
CLK high pulse width
2.5
2
-
-
2.7
2.5
-
-
ns
ns
2
3
(February, 2002, Version 3.0)
6
AMIC Technology, Inc.