欢迎访问ic37.com |
会员登录 免费注册
发布采购

AS8501 参数 Datasheet PDF下载

AS8501图片预览
型号: AS8501
PDF下载: 下载PDF文件 查看货源
内容描述: 高精确度的电压和电流测量传感器接口 [High precision voltage and current measurement sensor interface]
分类和应用: 传感器
文件页数/大小: 40 页 / 470 K
品牌: AMSCO [ AUSTRIAMICROSYSTEMS AG ]
 浏览型号AS8501的Datasheet PDF文件第1页浏览型号AS8501的Datasheet PDF文件第2页浏览型号AS8501的Datasheet PDF文件第3页浏览型号AS8501的Datasheet PDF文件第4页浏览型号AS8501的Datasheet PDF文件第6页浏览型号AS8501的Datasheet PDF文件第7页浏览型号AS8501的Datasheet PDF文件第8页浏览型号AS8501的Datasheet PDF文件第9页  
AS8501 -
Preliminary Data Sheet
austriamicrosystems
6
Electrical characteristics
VDDA=5V +/-0.1 V, fclk=8.192 MHz, chopping ratio MM=4 (see 7.5.3), oversampling frequency=2.048 MHz, oversampling ratio=128
temperature range : -40 to 125°C if not otherwise noted
symbol
parameter
conditions
min
typ
max
units
input characteristics
for gain 1 the input signal is connected directly to th input of the converter, this is not possible for the RSHH-RSHL
G1
input
Gain
gains of PGA
6, 24, 50, 100
AC_g6
Accuracy at gain 6
0 to 85 °C
1.0
% @-120mV
-40 to 125°C
1.5
% @-120mV
AC_g24
Accuracy at gain 24
0 to 85 °C
0.5
0.08
% @+-20mV
-40 to 125°C
1.5
0.3
% @+-20mV
AC_g50
Accuracy at gain 50
0 to 85 °C
1.0
% @+-10mV
AC_g100
Accuracy at gain 100
0 to 85 °C
1.0
% @+-5mV
Vin
input voltage ranges
G1
-350
-300 to + 800
900
mV
(with reference to RSHL)
G6
-200
+/- 120
160
mV
G24
-40
+/- 30
40
mV
G50
-20
+/- 15
20
mV
G100
-10
+/- 7.5
10
mV
1)
2)
3),4)
2)
3) 4)
4)
4)
5) 6)
5) 7)
5) 7)
5) 8)
5) 8)
Notes:
1)
the absolute gain values are subjected to a manufacturing spread of +/-30% max in the full temperature range. all gain values can be digitally
calibrated together with the external circuitry with a resolution better than 0.065%
2)
Current measurement paths for G6 and G24 are trimmed for minimum Temperature coefficient. The trimm algorithm is based on a 2 temperature
measurement at 23°C and 60°C.
Accuracy is mainly determined by bandgap characteristic and gain variation over temperature.
A TC shift of typically -15 ppm/K will occure during solder process which is compensated by a systematic offset during trimming.
3)
due to a nonlinear behaviour of the gain and reference voltage over temperature the accuracy is lower for the extended temperature range.
4)
The minimum limits for G50, G100 are derived from device characterization and not tested. Towards 125°C the TC values are higher.
therefore it is recommended to use these gain settings only for applications in the temperature range 0 to 85°C.
5)
if not otherwise specified the ranges are calibrated to the typical values. The maximum and minimum value represent the maximum usable span
accepting linearity deviation up to 1000 digits. Min, max limits are tested at room temperature only!
6)
this gain range is not using the internal PGA, the input is directely connected to the AD-converter. Therefore the input resistance is lower then for
other gain ranges.
It has been designed mainly for positive input voltages up to 0.8 V i.e. for measurements of temperature with transistors and diodes.
The limitation for negative input voltages is due to the onset of conduction of the input protection diodes.
7)
the ASIC is optimised for G6 and G24 concerning linearity, speed and TC, therefore these ranges are recommended whenever possible.
8)
because of higher TC value at elevated temperature G50 and G100 are recommended for applications in the temperature range 0 to 85°C
Revision 1.1, 04-April-06
www.austriamicrosystems.com
Page 5 of 40