Safe, Automated Operation
Convenient
●
Continuous full-auto withstanding voltage and insulation resistance testing
The 3174 lets you
set independent test conditions including
test voltage for withstanding voltage and insulation
resistance testing,
and you can perform these tests
continuously. Press the W
→
I key to automatically perform
withstanding voltage followed by insulation resistance tests,
or press the I
→
W key to automatically perform insulation
resistance followed by withstanding voltage tests.
RS-232C
Enables remote control.
3
3
Safe
●
Interlock function
Signal input from an external device such as an automatic
tester can be used to disable output and prevent testing,
ensuring safety during automatic testing and other uses.
GP-IB (option)
Enables remote control.
Contact check
LOW: A break in the lead is determined to have
occurred when the check current is not detected.
HIGH: A break in the lead is determined
to have occurred when the contact check
measurement voltage falls outside the range
defined by the upper and lower thresholds.
(Connectors are locked in place as shown
on the left to prevent the leads from
being disconnected.)
*Requires an additional pair of
9615 HIGH-VOLTAGE TEST LEADS.
Power cord inlet
Rear panel voltage output terminals
Status out relay terminals
Maximum input voltage: AC 150 V, DC 30 V
Maximum contact current: 0.5 A
The rear panel terminals are connected
at all times to the front terminals. When
embedding the 3174 HiTESTER inside
an automatic tester, connections can be
made via the rear panel terminals.
An OR operation applied to various enabled conditions
determines whether relay terminal output is turned on. Devices
such as the 9616 WARNING LAMP can be connected.
1. H.V.ON
2. TEST
3. PASS
4. FAIL
5. INT.LOCK
6. READY
7. EXT.CONT.
8. POWER.ON
Output voltage generation
Testing in progress
PASS state
FAIL state
Interlocked state
Ready state
Under external control
When the 3174 is on
9616 WARNING LAMP
(option)
(AC100V,0.1A)
Buzzer volume knobs
The 3174 provides separate
volume adjustments for the PASS
and FAIL judgment buzzers.
(Includes warning lamp unit only.
Refer to the included plans and drill
installation holes in a base such as a
metal plate as necessary.)
External I/O connector (Signal lines have photocoupler isolation.)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15-18
22-25
27
28-29
33-36
I/O
OUT
OUT
OUT
OUT
OUT
OUT
IN
IN
IN
IN
OUT
OUT
OUT
OUT
IN
IN
IN
OUT
OUT
Signa
READY
L-FAIL
U-FAIL
PASS
TEST
H.V.ON
EXT-E
START
STOP
INT.LOCK
W-MODE
I-MODE
W-FAIL
I-FAIL
ISO.COM
MEM-0 to 3
MEM-E
MODE-0,1
ISO.DCV
Low in ready state
Low in FAIL state (lower bound)
Low in FAIL state (upper bound)
Low in PASS state
Function
■
Interface specifications
E X T I / O
:
Output signals
Low in test sate
Low when voltage is present at output terminals
When low, external I/O input signals are enabled
When low, same function as START key
When low, same function as STOP key
Interlock on open
Low during withstanding voltage testing
Low during insulation resistance testing
Low in FAIL state during withstand voltage testing
Low in FAIL state during insulation resistance testing
Ground inputs for external devices
Saved test selected pins
When low, enables memory selected pins
Current test mode
Internal DC 15 V power supply (100 mA)
Open collector output (with photocoupler isolation)
All active low with a maximum load voltage of DC 30 V
Maximum output current: DC 100 mA per signal
Output saturation voltage: DC 1.5 V or less
Input signals
All active low input (with photocoupler isolation)
Maximum applied voltage: 30 V
High level voltage: from DC 15 V to 30 V, or open
Low level voltage: DC 5 V or less (-6 mA typ.)
EXT SW
:
Input signals (contact input)
START, STOP, SW.EN (external switch terminal enable)
Output signals
LED activation signal (maximum load current: 40 mA)