Absolute Maximum Ratings
Parameter
Storage Temperature
Ambient Operating Temperature
Relative Humidity
Supply Voltage
Control Input Voltage
Symbol
T
S
T
A
RH
V
CC
T, R
V
IN
Minimum
-50
-50
5
-0.5
-0.5
Maximum
+100
+100
95
4.0
V
CC
+ 0.5
Unit
°C
°C
%
V
V
Notes
1, 2
1, 2
1
1, 2, 3
1
Notes:
1. Absolute Maximum Ratings are those values beyond which damage to the device may occur if these limits are exceeded for other than a short period
of time. See Reliability Data Sheet for specific reliability performance.
2. Between Absolute Maximum Ratings and the Recommended Operating Conditions functional performance is not intended, device reliability is not
implied, and damage to the device may occur over an extended period of time.
3. See Figure 3 for the recommended power connection.
Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Case Operating Temperature
Module Supply Voltage
Data Rate
Symbol
T
A
T
C
V
CC
T, R
Minimum
-10
-10
2.97
1.0625
Maximum
+75
+85
3.63
1.25
Unit
°C
°C
V
Gb/s
Notes
1
2
2
2
Notes:
1. The Ambient Operating Temperature limitations are based on the Case Operating Temperature limitations and are subject to the host system thermal
design.
2. Recommended Operating Conditions are those values for which functional performance and device reliability is implied.
Transceiver Electrical Characteristics
T
C
= -10 °C to +85 °C, V
CC
T, V
CC
R = 3.3 V ± 10%
Parameter
Symbol
AC Electrical Characteristics
Power Supply Noise Rejection (pk-pk)
DC Electrical Characteristics
Module Supply Current
Power Dissipation
Sense Outputs:
Output High
Transmit Fault (TX_FAULT)
Loss of Signal - RX_LOS
MOD_DEF2
Output Low
Transmit Fault (TX_FAULT)
Loss of Signal - RX_LOS
MOD_DEF0
Control Inputs:
Input High
Transmit Disable (TX_DISABLE)
MOD-DEF1
MOD-DEF2
Input Low
Transmit Disable (TX_DISABLE)
MOD-DEF1
MOD-DEF2
V
IL
V
IH
V
OL
V
OH
I
CC
P
DISS
PSNR
Minimum
Typical
100
Maximum
Unit
mV
Notes
1
210
765
mA
mW
2.4
V
CC
T, R + 0.3
V
2
0.4
V
2
2.0
V
CC
V
2
0
0.8
V
2
Notes:
1. Filter per SFP specification is required on host board to remove 10 Hz to 2 MHz content.
2. Pulled up externally with a 4.7 k – 10 kW resistor on the host board to 3.3 V.