Microwave MLC’s
SQ Series Available Capacitance/Size/WVDC/T.C.
Case Size A
TABLE I: TC: M (+90±20PPM/°C)
Cap. pF
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
Cap. Tol.
B
B
B,C
B,C
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
WVDC
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
Cap. pF
1.7
1.8
1.9
2.0
2.2
2.4
2.7
3.0
3.3
3.6
3.9
4.3
4.7
5.1
5.6
Cap. Tol.
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
WVDC
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
Cap. pF
6.2
6.8
7.5
8.2
9.1
10
11
12
13
15
16
18
20
22
24
Cap. Tol.
B, C, D
B, C, J, K
B, C, J, K
B, C, J, K
B, C, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
WVDC
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
Cap. pF
27
30
33
36
39
43
47
51
56
62
68
75
82
91
100
Cap. Tol.
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
WVDC
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
TABLE II: TC: A (0±30PPM/°C)
Cap. pF
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
2.2
2.4
Cap. Tol.
B
B
B,C
B,C
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
WVDC
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
Cap. pF
2.7
3.0
3.3
3.6
3.9
4.3
4.7
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
11
12
13
15
16
18
Cap. Tol.
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, D
B, C, J, K
B, C, J, K
B, C, J, K
B, C, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
WVDC
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
150, 250
Cap. pF
20
22
24
27
30
33
36
39
43
47
51
56
62
68
75
82
91
100
110
120
130
Cap. Tol.
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
Cap. pF
WVDC
150, 250 150
150, 250 160
150, 250 180
150, 250 200
150, 250 220
150, 250 240
150, 250 270
150, 250 300
150, 250 330
150, 250 360
150, 250 390
150, 250 430
150, 200 470
150, 200 510
150, 200 560
150, 200 620
150, 200 680
750
150
820
150
910
150
1000
150
Cap. Tol.
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
F, G, J, K
WVDC
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
50
50
50
50
50
TABLE III: TC: C (±15%)
Cap. pF
1000
1200
1500
1800
2000
Cap. Tol.
K, M, N
K, M, N
K, M, N
K, M, N
K, M, N
WVDC
50
50
50
50
50
Cap. pF
2200
2700
3300
3900
4700
Cap. Tol.
K, M, N
K, M, N
K, M, N
K, M, N
K, M, N
WVDC
50
50
50
50
50
Cap. pF
5100
5600
6800
8200
10000
Cap. Tol.
K, M, N
K, M, N
K, M, N
K, M, N
K, M, N
WVDC
50
50
50
50
50
8
121