型号: ADS1256IDBT
PDF下载: 下载PDF文件 查看货源
内容描述: 极低噪声, 24位模拟数字转换器 [Very Low Noise, 24-Bit Analog-to-Digital Converter]
分类和应用: 转换器
文件页数/大小: 39 页 / 422 K
品牌: BURR-BROWN [ BURR-BROWN CORPORATION ]
 浏览型号ADS1256IDBT的Datasheet PDF文件第1页浏览型号ADS1256IDBT的Datasheet PDF文件第3页浏览型号ADS1256IDBT的Datasheet PDF文件第4页浏览型号ADS1256IDBT的Datasheet PDF文件第5页浏览型号ADS1256IDBT的Datasheet PDF文件第6页浏览型号ADS1256IDBT的Datasheet PDF文件第7页浏览型号ADS1256IDBT的Datasheet PDF文件第8页浏览型号ADS1256IDBT的Datasheet PDF文件第9页  
ADS1255
ADS1256
www.ti.com
SBAS288D − JUNE 2003 − REVISED AUGUST 2004
ORDERING INFORMATION
(1)
PRODUCT
ADS1255
ADS1256
PACKAGE-LEAD
SSOP-20
SSOP-28
PACKAGE
DESIGNATOR
DB
DB
PACKAGE
MARKING
ADS1255IDB
ADS1256IDB
ORDERING NUMBER
ADS1255IDBT
ADS1255IDBR
ADS1256IDBT
ADS1256IDBR
(1) For the most current package and ordering information, refer to our web site at www.ti.com.
TRANSPORT MEDIA,
QUANTITY
Tape and Reel, 250
Tape and Reel, 1000
Tape and Reel, 250
Tape and Reel, 1000
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range unless otherwise noted(1)
ADS1255, ADS1256
AVDD to AGND
DVDD to DGND
AGND to DGND
Input Current
Analog inputs to AGND
DIN, SCLK, CS, RESET,
SYNC/PDWN,
XTAL1/CLKIN to DGND
D0/CLKOUT, D1, D2, D3
to DGND
−0.3 to +6
−0.3 to +3.6
−0.3 to +0.3
100, Momentary
10, Continuous
−0.3 to AVDD + 0.3
−0.3 to +6
UNIT
V
V
V
mA
mA
V
V
This integrated circuit can be damaged by ESD. Texas
Instruments recommends that all integrated circuits be
handled with appropriate precautions. Failure to observe
proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to
complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could
cause the device not to meet its published specifications.
Digital
inputs
−0.3 to DVDD + 0.3
+150
−40 to +105
−60 to +150
V
°C
°C
°C
Maximum Junction Temperature
Operating Temperature Range
Storage Temperature Range
Lead Temperature (soldering, 10s)
+300
°C
(1) Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to
absolute maximum conditions for extended periods may degrade
device reliability. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond
those specified is not implied.
2