ELECTRICAL SPECIFICATIONS
T
A
= T
MIN
– T
MAX
, V
CC
= +5.0 V, V
EE
= –5.2 V, R
SET
= 7.5 kΩ, Control Amp In = Ref Out, V
OUT
= 0 V, unless otherwise specified.
PARAMETERS
Power Supply Requirements
Positive Supply Voltage
Negative Supply Voltage
Positive Supply Current (+5.0 V)
Negative Supply Current (–5.2 V)
Nominal Power Dissipation
Power Supply Rejection Ratio
Voltage Input and Control
Reference Input Impedance
Ref. Multiplying Bandwidth
Internal Reference Voltage
Internal Reference Voltage Drift
Amplifier Input Impedance
Amplifier Input Bandwidth
Digital Inputs
Logic 1 Voltage
Logic 0 Voltage
Logic 1 Current
Logic 0 Current
Input Capacitance
Input Setup Time – t
S
Input Setup Time – t
S
Input Hold Time – t
H
Input Hold Time – t
H
Latch Pulse Width – t
PWL
, t
PWH
TEST
CONDITIONS
TEST
LEVEL
IV
IV
I
VI
I
VI
V
I
SPT9713A
MIN TYP MAX
4.75
–5.46
5.0
–5.2
8
115
640
30
+5.25
–4.94
14
16
140
148
100
SPT9713B
MIN TYP MAX
4.75
–5.46
5.0
–5.2
8
115
640
30
+5.25
–4.94
14
16
140
148
100
UNITS
V
V
mA
mA
mA
mA
mW
µA/V
+25 °C
Full Temp.
+25 °C
Full Temp
±5% of V
EE
and V
CC
External Ref, +25 °C
+25 °C
+25 °C
Full
+25 °C
+25 °C
Full Temp.
Full Temp.
Full Temp.
Full Temp.
+25 °C
+25 °C
Full Temp.
+25 °C
Full Temp.
+25 °C
V
V
VI
V
V
V
VI
VI
VI
VI
V
IV
IV
IV
IV
IV
3
40
–1.15 –1.20 –1.25
50
3
1
2.0
0.8
20
600
3
3.5
0.5
0.5
5.0
3
2
0
4.0
3
40
–1.15 –1.20 –1.25
50
3
1
2.0
0.8
20
600
3
3.5
0.5
0.5
5.0
3
2
0
4.0
kΩ
MHz
V
ppm/°C
MΩ
MHz
V
V
µA
µA
pF
ns
ns
ns
ns
ns
TEST LEVEL CODES
All electrical characteristics are subject to the
following conditions:
All parameters having min/max specifications
are guaranteed. The Test Level column indi-
cates the specific device testing actually per-
formed during production and Quality Assur-
ance inspection. Any blank section in the data
column indicates that the specification is not
tested at the specified condition.
LEVEL
I
II
III
IV
V
VI
TEST PROCEDURE
100% production tested at the specified temperature.
100% production tested at T
A
= +25 °C, and sample tested at the
specified temperatures.
QA sample tested only at the specified temperatures.
Parameter is guaranteed (but not tested) by design and characteri-
zation data.
Parameter is a typical value for information purposes only.
100% production tested at T
A
= +25 °C. Parameter is guaranteed
over specified temperature range.
SPT9713
3
2/15/01