CALIFORNIA MICRO DEVICES
Typical DC Characteristics
Unless stated otherwise, all DC characteristics were
measured at room temperature with a nominal V
CC
supply voltage of 5V and an output capacitance of 10µF.
Resistive load conditions were used.
Line Regulation Characteristics
of the regulator are
shown in Figure 1. At maximum rated load conditions
(500mA), a 100mV drop in regulation occurs when the
line voltage has collapses below 3.8V. For light load
conditions (5mA), regulation is maintained for line
voltages as low as 3.3V.
3.35
3.30
3.25
VOUT (V)
CMPWR160
5mA Load
500mA Load
3.20
3.15
3.10
3.05
3.0
3.5
4.0
VCC (V)
4.5
5.0
Figure 1. Line Regulation
VOUT (V)
Load Regulation
performance is shown from zero to
maximum rated load in Figure 2. A 10% to 100% change
of rated load, results in an output voltage change of less
than 10mV. This translates into an effective output
impedance of approximately 0.02Ω.
3.40
3.35
3.30
3.25
3.20
0
200
400
600
Load Current (mA)
Figure 2. Load Regulation
Ground Current (µA)
Ground Current
is shown across the entire range of
load conditions in Figure 3. The ground current increases
by 40µA across the range of load conditions. This
increase is due to the current limiting protective circuitry
becoming active.
100
80
60
40
20
0
0
200
400
600
Load Current (mA)
Figure 3. Ground Current
©2000 California Micro Devices Corp. All rights reserved. SmartOR™ is a trademark of California Micro Devices Corporation.
4
215 Topaz Street, Milpitas, California 95035
Tel: (408) 263-3214
Fax: (408) 263-7846
www.calmicro.com
12/5/2000