CALIFORNIA MICRO DEVICES
Typical DC Characteristics
continued
V
CC
Operating Current (no load,
SD
high)
is shown
across a range of V
CC
supply voltages with the regulator
enabled in Figure 4. The graph shows that the operating
current is 35µA typical and changes by less than 1µA
across this range.
60
50
Supply Current (µA)
40
30
20
10
0
3.5
CMPWR160
4.5
V
CC
(V)
5.5
Figure 4. V
CC
Operating Current (no load)
V
CC
Shutdown Current
variation with the V
CC
supply
voltage is shown in Figure 5.
Supply Current (µA)
10
8
6
4
2
0
1.5
2.5
3.5
V
CC
(V)
4.5
5.5
Figure 5. V
CC
Shutdown Current
©2000 California Micro Devices Corp. All rights reserved. SmartOR™ is a trademark of California Micro Devices Corporation.
215 Topaz Street, Milpitas, California 95035
12/5/2000
Tel: (408) 263-3214
Fax: (408) 263-7846
www.calmicro.com
5