T
YPICAL PERFORMANCE CURVES
250
LOAD CAPACITANCE vs INPUT RISE TIME
(All 5 Vout Models)
75
LOAD CAPACITANCE vs INPUT RISE TIME
(All 12 Vout Models)
Capacitance
(µF)
Capacitance
(µF)
200
150
100
50
0
0
5
10
(mS)
15
20
SAFE
OPERATING
AREA
60
45
30
15
0
0
5
10
(mS)
15
20
SAFE
OPERATING
AREA
LOAD CAPACITANCE vs INPUT RISE TIME
(All 15 Vout Models)
50
100%
EFFICIENCY vs LOAD
Capacitance
(µF)
40
30
20
10
0
0
5
10
(mS)
VOUT vs LOAD
(All Models Normalized)
15
20
SAFE
OPERATING
AREA
Efficiency
50%
10%
0%
25%
50%
Load
75%
100%
NOTES:
1.) When operated within the SAFE OPERATING AREA as defined
by the above curves, the output voltage of HL02U devices is
guaranteed to be within 95% of its steady-state value within 100
milliseconds after the input voltage has reached 95% of its steady-
state value.
2.) For dual output models, total load capacitance is the sum of the
capacitances on the plus and minus outputs.
110%
Vout
100%
90%
25%
50%
75%
Load
100%
125%
Page 4