 浏览型号CAT1023WI-28-T3的Datasheet PDF文件第5页浏览型号CAT1023WI-28-T3的Datasheet PDF文件第6页浏览型号CAT1023WI-28-T3的Datasheet PDF文件第7页浏览型号CAT1023WI-28-T3的Datasheet PDF文件第8页浏览型号CAT1023WI-28-T3的Datasheet PDF文件第10页浏览型号CAT1023WI-28-T3的Datasheet PDF文件第11页浏览型号CAT1023WI-28-T3的Datasheet PDF文件第12页浏览型号CAT1023WI-28-T3的Datasheet PDF文件第13页  
CAT1021, CAT1022, CAT1023
EMBEDDED EEPROM OPERATION
The CAT1021/22/23 feature a 2-kbit embedded serial
EEPROM that supports the I
2
C Bus data transmission
protocol. This Inter-Integrated Circuit Bus protocol
defines any device that sends data to the bus to be a
transmitter and any device receiving data to be a
receiver. The transfer is controlled by the Master
device which generates the serial clock and all
START and STOP conditions for bus access. Both the
Master device and Slave device can operate as either
transmitter or receiver, but the Master device controls
which mode is activated.
I C BUS PROTOCOL
The features of the I
2
C bus protocol are defined as
follows:
(1) Data transfer may be initiated only when the bus
is not busy.
(2) During a data transfer, the data line must remain
stable whenever the clock line is high. Any
changes in the data line while the clock line is
high will be interpreted as a START or STOP
condition.
START CONDITION
The START Condition precedes all commands to the
device, and is defined as a HIGH to LOW transition of
Figure 3. Bus Timing
tF
tLOW
SCL
tSU:STA
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
tHIGH
tLOW
tR
SDA when SCL is HIGH. The CAT1021/22/23 monitor
the SDA and SCL lines and will not respond until this
condition is met.
STOP CONDITION
A LOW to HIGH transition of SDA when SCL is HIGH
determines the STOP condition. All operations must
end with a STOP condition.
DEVICE ADDRESSING
The Master begins a transmission by sending a
START condition. The Master sends the address of
the particular slave device it is requesting. The four
most significant bits of the 8-bit slave address are
programmable in metal and the default is 1010.
The last bit of the slave address specifies whether a
Read or Write operation is to be performed. When this
bit is set to 1, a Read operation is selected, and when
set to 0, a Write operation is selected.
After the Master sends a START condition and the
slave address byte, the CAT1021/22/23 monitors the
bus and responds with an acknowledge (on the SDA
line) when its address matches the transmitted slave
address. The CAT1021/22/23 then perform a Read or
¯¯
Write operation depending on the R/W bit.
2
SDA IN
tAA
SDA OUT
tDH
tBUF
Figure 4. Write Cycle Timing
SCL
SDA
8TH BIT
BYTE n
ACK
tWR
STOP
CONDITION
START
CONDITION
ADDRESS
© Catalyst Semiconductor, Inc.
Characteristics subject to change without notice
9
Doc. No. MD-3009 Rev. M