 浏览型号CL-L400-MC1L1-A的Datasheet PDF文件第4页浏览型号CL-L400-MC1L1-A的Datasheet PDF文件第5页浏览型号CL-L400-MC1L1-A的Datasheet PDF文件第6页浏览型号CL-L400-MC1L1-A的Datasheet PDF文件第7页浏览型号CL-L400-MC1L1-A的Datasheet PDF文件第8页浏览型号CL-L400-MC1L1-A的Datasheet PDF文件第10页浏览型号CL-L400-MC1L1-A的Datasheet PDF文件第11页浏览型号CL-L400-MC1L1-A的Datasheet PDF文件第12页  
DATA SHEET
9. Precautions
9-1 Handling precaution
(1). Avoid the application of any stress to the encupsulant.
(2). Avoid any contact by a sharp metal nail or other materials with the encupsulant.
encupsulant
(Hatching area)
9/12
(3).Pick and Place
 Recommend
condition : nozzle inner radius
≧φ4.4mm
 Avoid
direct contact to the encapsulant with the nozzle.
φ =4.4mm
NG
ex : pick up area
Bad ex : narrow nozzle
(4). PCB handling
Bending the circuit board with soldered LEDs may cause breakage of LEDs.
Please take care to bow, twist, and warpage the PCB.
Cathode mark
9-2. Lighting at a low current
A minimum current value of lighting of all dice is 30mA.
When a minimal current is applied, LED dice may look different in their brightness due to
the individual difference of the LED element, and it is not a failed product.
9-3. Handling of static electricity
- These products are sensitive to static electricity charge.
Please take measures to prevent any static electricity being produced such as the wearing of a
wristband or anti-static gloves when handling this product.
- All devices, equipment and machinery must be properly grounded. It is recommended that precautions
be taken against surge voltage to the equipment that mounts the LEDs.
- When inspecting the final products in which LEDs were assembled, it is recommended to check
whether the assembled LEDs are damaged by static electricity or not.
- It is easy to find static-damaged LEDs by a light-on test.
<Light-on test criterion>
Judgmental criterion
Condition
I
F
=6mA/PKG
No-lighting die in package is
unacceptable
Symbol
Name
CITILED
CL-L400-MC1L1-A
CITIZEN ELECTRONICS CO., LTD. JAPAN
Ref.CE-P1158 05/11