欢迎访问ic37.com |
会员登录 免费注册
发布采购

MFL283R3S/ES 参数 Datasheet PDF下载

MFL283R3S/ES图片预览
型号: MFL283R3S/ES
PDF下载: 下载PDF文件 查看货源
内容描述: MFL单路和双路DC / DC转换器 [MFL Single and Dual DC/DC Converters]
分类和应用: 转换器局域网
文件页数/大小: 13 页 / 217 K
品牌: CRANE [ Crane Aerospace & Electronics. ]
 浏览型号MFL283R3S/ES的Datasheet PDF文件第2页浏览型号MFL283R3S/ES的Datasheet PDF文件第3页浏览型号MFL283R3S/ES的Datasheet PDF文件第4页浏览型号MFL283R3S/ES的Datasheet PDF文件第5页浏览型号MFL283R3S/ES的Datasheet PDF文件第7页浏览型号MFL283R3S/ES的Datasheet PDF文件第8页浏览型号MFL283R3S/ES的Datasheet PDF文件第9页浏览型号MFL283R3S/ES的Datasheet PDF文件第10页  
Crane Aerospace & Electronics Power Solutions
MFL Single and Dual DC/DC Converters
28 VOLT INPUT – 65 WATT
Electrical Characteristics: –55°C to +125° C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
OUTPUT POWER
OUTPUT RIPPLE
VOLTAGE 10 k - 2 MHz
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
CONDITION
Tc = 25°C
V
IN
= 16 TO 40 VDC
V
IN
= 16 TO 40 VDC
Tc = 25°C
Tc = –55°C to +125°C
V
IN
= 16 to 40 VDC
NO LOAD TO FULL
CONTINUOUS
TRANSIENT
1,
3
50 ms
NO LOAD
INHIBITED - INH1
INHIBITED - INH2
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT
10 kHz - 10 MHz
Tc = 25°C
POWER DISSIPATION
SHORT CIRCUIT
Tc = 25°C
RECOVERY
1
STEP LOAD RESP.
50% – 100% – 50%
TRANSIENT
RECOVERY
1,
4
STEP LINE RESP.
16 – 40 – 16 VDC
TRANSIENT
1,
5
RECOVERY
1,
4
DELAY
OVERSHOOT
1
Tc=25°C
1,
7
MFL283R3S
MIN
3.26
0
0
16
73
TYP MAX
3.3 3.34
— 12.12
2
10
10
0
28
70
9
35
15
40
2
35
50
20
40
40
50
100
14
70
50
MFL2805S
MIN
4.95
0
0
16
77
TYP MAX
5.00 5.05
15
30
0
28
70
9
35
15
80
10
50
35
50
20
20
40
50
120
14
70
50
MFL2812S
MIN TYP MAX
11.88 12.00 12.12
0
0
16
83
30
45
0
28
50
9
35
15
86
5
60
75
100
20
20
40
50
100
14
70
50
mA pp
%
UNITS
VDC
A
W
mV p-p
mV
mV
VDC
V
mA
mA
12.5
1.5
200
1.5
250
200
3.5
0
20
4
400
3.0
300
600
6
25
1000
12.5
1.5
250
1.5
250
200
3.5
0
16
4
350
3.0
300
300
6
25
1000
10
1.5
450
1.5
250
200
3.5
0
14
4
600
3.0
400
300
6
50
1000
W
ms
mV pk
ms
mV pk
μs
ms
mV pk
μF
START-UP
6
C
OUT
Notes
1. Guaranteed by design, not tested.
2. MFL283R3S current and power maximum are at 25°C only.
3. Unit will shut down above approximately 45V but will be undamaged and
will restart when voltage drops into normal range.
4. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
5. Transition time > 10 μs.
6. Tested on release from inhibit.
7. Shall not compromise DC performance
www.craneae.com
Page 6 of 13
Rev D - 20060601