欢迎访问ic37.com |
会员登录 免费注册
发布采购

MFL283R3S/ES 参数 Datasheet PDF下载

MFL283R3S/ES图片预览
型号: MFL283R3S/ES
PDF下载: 下载PDF文件 查看货源
内容描述: MFL单路和双路DC / DC转换器 [MFL Single and Dual DC/DC Converters]
分类和应用: 转换器局域网
文件页数/大小: 13 页 / 217 K
品牌: CRANE [ Crane Aerospace & Electronics. ]
 浏览型号MFL283R3S/ES的Datasheet PDF文件第4页浏览型号MFL283R3S/ES的Datasheet PDF文件第5页浏览型号MFL283R3S/ES的Datasheet PDF文件第6页浏览型号MFL283R3S/ES的Datasheet PDF文件第7页浏览型号MFL283R3S/ES的Datasheet PDF文件第9页浏览型号MFL283R3S/ES的Datasheet PDF文件第10页浏览型号MFL283R3S/ES的Datasheet PDF文件第11页浏览型号MFL283R3S/ES的Datasheet PDF文件第12页  
Crane Aerospace & Electronics Power Solutions
MFL Single and Dual DC/DC Converters
28 VOLT INPUT – 65 WATT
Electrical Characteristics: –55°C to +125° C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
2
V
IN
= 16 TO 40 VDC
OUTPUT POWER
2
OUTPUT RIPPLE
VOLTAGE +/– V
OUT
LINE REGULATION
V
IN
= 16 TO 40 VDC
LOAD REGULATION
NO LOAD TO FULL
CROSS REGULATION
Tc = 25°C
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
10 kHz - 2 MHz
+V
OUT
–V
OUT
+V
OUT
–V
OUT
SEE NOTE 3
SEE NOTE 4
CONTINUOUS
TRANSIENT
1,
5
50 ms.
NO LOAD
INHIBITED - INH1
INHIBITED - INH2
10 kHz - 10 MHz
BALANCED LOAD
POWER DISSIPATION
SHORT CIRCUIT
Tc = 25°C
RECOVERY
1
50 %–100%– 50% LOAD
TRANSIENT
RECOVERY
1,
6
16 – 40 – 16 V
IN
TRANSIENT
1,
7
RECOVERY
1,
6
START–UP
8
C
OUT
DELAY
OVERSHOOT
1
Tc=25°C
1,9
16
0
77
50
0
25
0
25
5
3
28
50
9
35
15
80
100
50
100
50
100
8
6
40
50
120
14
70
50
16
0
83
50
0
25
10
50
2
2
28
50
9
35
15
86
120
50
100
50
120
4
4
40
50
100
14
70
50
16
0
84
50
0
25
10
50
2
2
28
50
9
35
15
87
150
50
100
50
150
4
4
40
50
100
14
70
50
mV
%
VDC
V
mA
mA
mA p-p
%
mV p-p
mV
MFL2805D
MIN TYP MAX
4.95 5.00 5.05
4.92 5.00 5.08
0
0
0
7
10
50
MFL2812D
MIN TYP MAX
11.88 12.00 12.12
11.82 12.00 12.18
0
0
0
3.5
5
60
MFL2815D
MIN TYP MAX
14.85 15.00 15.15
14.77 15.00 15.23
0
0
0
3.03
4.34
65
W
CONDITIONS
+V
OUT
Tc = 25°C
–V
OUT
EACH OUTPUT
TOTAL OUTPUT
V
IN
= 16 TO 40 VDC
UNITS
VDC
A
INPUT RIPPLE
CURRENT
EFFICIENCY 25°C Tc
LOAD FAULT
12.5
1.5
250
1.5
250
200
3.5
0
16
4.0
350
3.0
300
300
6
25
500
10
1.5
450
1.5
250
200
3.5
0
14
4.0
600
3.0
400
300
6
50
500
10
1.5
500
1.5
250
200
3.5
0
14
4.0
600
3.0
400
300
6
50
500
W
ms
mV pk
ms
mV pk
μs
ms
mV p
μF
STEP LOAD RESP.
± V
OUT
STEP LINE RESP.
± V
OUT
Notes
1. Guaranteed by design, not tested.
2. Up to 70% of the total output power is available from either output
providing the opposite output is simultaneously carrying 30% of the
total power.
3. Effect on negative Vout from 50%/50% loads to 70%/30% or
30%/70% loads.
4. Effect on negative Vout from 50%/50% loads to +Pout=50%,
-Pout=10%.
5. Unit will shut down above approximately 45V but will be undamaged
and will restart when voltage drops into normal range.
6. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
7. Transition time > 10 μs.
8. Tested on release from inhibit.
9. Shall not compromise DC performance
www.craneae.com
Page 8 of 13
Rev D - 20060601