CY7C185
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
Supply Voltage to Ground Potential ............... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State
[2]
............................................ –0.5V to +7.0V
DC Input Voltage
[2]
........................................ –0.5V to +7.0V
Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage .......................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current.................................................... >200 mA
Operating Range
Range
Commercial
Industrial
Ambient
Temperature
0
°
C to +70
°
C
–40
°
C to +85
°
C
V
CC
5V
±
10%
5V
±
10%
Electrical Characteristics
Over the Operating Range
7C185–15
Parameter
V
OH
V
OL
V
IH
V
IL
I
IX
I
OZ
I
OS
I
CC
I
SB1
I
SB2
Description
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
[2]
Input Load Current
Output Leakage
Current
Output Short
Circuit Current
[3]
V
CC
Operating
Supply Current
Automatic
Power-Down Current
Automatic
Power-Down Current
GND
≤
V
I
≤
V
CC
GND
≤
V
I
≤
V
CC
,
Output Disabled
V
CC
= Max.,
V
OUT
= GND
V
CC
= Max.,
I
OUT
= 0 mA
Max. V
CC
, CE
1
≥
V
IH
or CE
2
≤
V
IL
Min. Duty Cycle=100%
Max. V
CC
, CE
1
≥
V
CC
– 0.3V,
or CE
2
≤
0.3V
V
IN
≥
V
CC
– 0.3V or V
IN
≤
0.3V
40
15
Test Conditions
V
CC
= Min., I
OH
= –4.0 mA
V
CC
= Min., I
OL
= 8.0 mA
2.2
–0.5
–5
–5
Min.
2.4
0.4
V
CC
+
0.3V
0.8
+5
+5
–300
130
20
15
2.2
–0.5
–5
–5
Max.
7C185–20
Min.
2.4
0.4
V
CC
+
0.3V
0.8
+5
+5
–300
110
Max.
Unit
V
V
V
V
µA
µA
mA
mA
mA
mA
Notes:
2. Minimum voltage is equal to –3.0V for pulse durations less than 30 ns.
3. Not more than 1 output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
Document #: 38-05043 Rev. **
Page 2 of 11