DS2107SY
CHARACTERISTICS
Symbol
V
FM
I
RM
Q
S
I
rr
V
TO
r
T
Parameter
Forward voltage
Peak reverse current
Total stored charge
Peak reverse recovery current
Threshold voltage
Slope resistance
Conditions
At 3000A peak, T
case
= 25
o
C
At V
RRM
, T
case
= 150
o
C
I
F
= 2000A, dI
RR
/dt = 3A/µs
T
case
= 150˚C, V
R
= 100V
At T
vj
= 150˚C
At T
vj
= 150˚C
Min.
-
-
-
-
-
-
Max.
1.275
250
5000
150
0.77
0.167
Units
V
mA
µC
A
V
mΩ
CURVES
5000
Measured under pulse conditions
T
j
= 150˚C
10000
4000
8000
Mean power dissipation - (W)
Instantaneous forward current, I
F
- (A)
3000
6000
2000
4000
1000
2000
dc
Half wave
3 phase
6 phase
0
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
00
Instantaneous forward voltage, V
F
-(V)
2000
4000
Mean forward current, I
F(AV)
- (A)
6000
Fig.2 Maximum (limit) forward characteristics
V
FM
Equation:-
V
FM
= A + Bln (I
F
) + C.I
F
+D.√I
F
Where
Fig.3 Dissipation curves
A = 0.671711
B = 0.011006
C = 0.000158
D = 0.000604
these values are valid for T
j
= 125˚C for I
F
500A to 5000A
4/7