EM83040B
LCD CONTROLLER
m in ar y
Preli
FUNCTION DESCRIPTIONS
(1)User can use MAIN pin to chose master unit or slave unit.
MAIN
1
Unit
MASTER
Function
Generate these signals:
Load, CA, CB, VSS2+, VSS2-, VSS3, VSS4, VOUT
Internal RC clock
Accept these Master unit signals
Load, VOUT, V1, V2, V3, V4, V5
No internal RC clock
0
SLAVE
(2)User can use M1,M2 to choose four modes. As followed
MASTER
MAIN
M1
M0
Segment
Mode1
1
0
0
O(16:1)=S(16:1)
Mode2
1
0
1
Mode3
1
1
0
O(32:1)=S(32:1)
Mode4
1
1
1
O(48:1)=S(48:1)
SLAVE
MAIN
M1
M0
Segment
Mode1
0
0
0
O(80:1)=S(80:1)
Mode2
0
0
1
O(80:1)=S(80:1)
Mode3
0
1
0
O(80:1)=S(80:1)
Mode4
0
1
1
O(80:1)=S(80:1)
* S=Segment, C=Common
* (M1, M0) for Master must same as Slave unit
(3)RAM control
Write mode
Common
O(80:17)=C(64:1)
O(80:1)=C(80:1)
O(80:33)=C(48:1)
O(80:49)=C(32:1)
Common
BIAS
1/9
1/9
1/7
1/5
BIAS
1/9
1/9
1/7
1/5
FIG. 3
LCD RAM can be written or read with control signal. The RAMEN pin can select a RAM which can be read or
write. The RAMADS pin can select whether
* This specification are subject to be changed without notice.
9.14.2001
6