eorex
Advanced Data Retention Current
Symbol
Parameter
PASR="000" (Full)
I
DD6
PASR="001" (2BK)
PASR="010" (1BK)
PASR="000" (Full)
I
DD6
PASR="001" (2BK)
PASR="010" (1BK)
PASR="000" (Full)
I
DD6
PASR="001" (2BK)
PASR="010" (1BK)
+70°C < TJ
≤
+85°C
CKE≤0.2V
+40°C < TJ
≤
+70°C
CKE≤0.2V
Conditions
-25°C
≤
TJ
≤
+40°C
CKE≤0.2V
EM42AM3284LBC
(TJ = –25 to +85°C, VDD and VDDQ = 1.7V to 1.9V, VSS and VSSQ = 0V)
Max.
300
250
220
560
390
300
800
650
500
Units
uA
uA
uA
uA
uA
uA
uA
uA
uA
Recommended DC Operating Conditions (Continued)
Symbol
I
IL
I
OL
V
OH
V
OL
Parameter
Input Leakage Current
Output Leakage Current
High Level Output Voltage
Low Level Output Voltage
Test Conditions
0≤V
I
≤V
DDQ
, V
DDQ
=V
DD
All other pins not under
test=0V
0≤V
O
≤V
DDQ
, D
OUT
is disabled
I
O
=-0.1mA
I
O
=+0.1mA
Min.
-2
-1.5
0.9*V
DDQ
0.1*V
DDQ
Typ.
Max.
+2
+1.5
Units
uA
uA
V
V
Jun. 2009
8/24
www.eorex.com