EM48BM0884VTA
Recommended DC Operating Conditions
(VDD=3.3V±0.3V)
Max.
Units
Symbol
Parameter
Test Conditions
-6
-7
Burst length=1, one bank
tRC≥tRC(min.), IOL=0mA,
One bank active
Operating Current (Note 1)
ICC1
105
105
mA
mA
ICC2P
CKE≤VIL(max.), tCK=min.
12
12
Precharge Standby Current in
Power Down Mode
ICC2PS
ICC2N
CKE≤VIL(max.), tCK= ∞
tCK=min.
5
5
mA
mA
mA
40
30
40
30
Precharge Standby Current in
Non-power Down Mode
ICC2NS
tCK= ∞
CKE≥VIL(min.), /CS=VIH
CKE≤VIL(max.),
power down mode
No Operating Current
tCK=min. /CS=VIH(min.)
4banks active
ICC3P
35
35
mA
ICC3N
ICC4
ICC5
ICC6
CKE≥VIL(min.)
65
65
mA
mA
Operating Current (Burst
Mode) (Note 2)
tCCD≥2CLKs, IOL=0mA
105
100
(Note 3)
tCK=min.
Standard
150
6
140
6
mA
mA
Auto Refresh Current
Self Refresh Current,
CKE≤0.2V
*All voltages referenced to VSS.
Note 1: ICC1 depends on output loading and cycle rates.
Specified values are obtained with the output open.
Input signals are changed only one time during tCK (min.)
Note 2: ICC4 depends on output loading and cycle rates.
Specified values are obtained with the output open.
Input signals are changed only one time during tCK (min.)
Note 3: Input signals are changed only one time during tCK (min.)
Recommended DC Operating Conditions (Continued)
(VDD=3.3V±0.3V)
Symbol
Parameter
Test Conditions
Min.
-10
Typ. Max. Units
0≤VI≤VDDQ, VDDQ=VDD
All other pins not under
test=0V
IIL
Input Leakage Current
-
+10
uA
IOL
VOH
VOL
Output Leakage Current
High Level Output Voltage
Low Level Output Voltage
-10
2.4
-
-
-
-
+10
-
uA
V
0≤VO≤VDDQ, DOUT is disabled
IO=-0.1mA
IO=+0.1mA
0.4
V
Aug. 2011
7/20