欢迎访问ic37.com |
会员登录 免费注册
发布采购

HT46R064B 参数 Datasheet PDF下载

HT46R064B图片预览
型号: HT46R064B
PDF下载: 下载PDF文件 查看货源
内容描述: 增强A / D型8位OTP MCU [Enhanced A/D Type 8-Bit OTP MCU]
分类和应用:
文件页数/大小: 96 页 / 533 K
品牌: HOLTEK [ HOLTEK SEMICONDUCTOR INC ]
 浏览型号HT46R064B的Datasheet PDF文件第19页浏览型号HT46R064B的Datasheet PDF文件第20页浏览型号HT46R064B的Datasheet PDF文件第21页浏览型号HT46R064B的Datasheet PDF文件第22页浏览型号HT46R064B的Datasheet PDF文件第24页浏览型号HT46R064B的Datasheet PDF文件第25页浏览型号HT46R064B的Datasheet PDF文件第26页浏览型号HT46R064B的Datasheet PDF文件第27页  
HT46R064B/065B/066B  
·
Indirect Addressing Program Example  
data .section ¢data¢  
adres1 db ?  
adres2 db ?  
adres3 db ?  
adres4 db ?  
block db ?  
code .section at 0 code  
org 00h  
start:  
mov a,04h  
; setup size of block  
mov block,a  
mov a,offset adres1  
mov mp0,a  
; Accumulator loaded with first RAM address  
; setup memory pointer with first RAM address  
loop:  
clr IAR0  
inc mp0  
sdz block  
jmp loop  
; clear the data at address defined by MP0  
; increment memory pointer  
; check if last memory location has been cleared  
continue:  
The important point to note here is that in the example shown above, no reference is made to specific Data Memory  
addresses.  
Accumulator - ACC  
Status Register - STATUS  
The Accumulator is central to the operation of any  
microcontroller and is closely related with operations  
carried out by the ALU. The Accumulator is the place  
where all intermediate results from the ALU are stored.  
Without the Accumulator it would be necessary to write  
the result of each calculation or logical operation such  
as addition, subtraction, shift, etc., to the Data Memory  
resulting in higher programming and timing overheads.  
Data transfer operations usually involve the temporary  
storage function of the Accumulator; for example, when  
transferring data between one user defined register and  
another, it is necessary to do this by passing the data  
through the Accumulator as no direct transfer between  
two registers is permitted.  
This 8-bit register contains the zero flag (Z), carry flag  
(C), auxiliary carry flag (AC), overflow flag (OV), power  
down flag (PDF), and watchdog time-out flag (TO).  
These arithmetic/logical operation and system manage-  
ment flags are used to record the status and operation of  
the microcontroller.  
With the exception of the TO and PDF flags, bits in the  
status register can be altered by instructions like most  
other registers. Any data written into the status register  
will not change the TO or PDF flag. In addition, opera-  
tions related to the status register may give different re-  
sults due to the different instruction operations. The TO  
flag can be affected only by a system power-up, a WDT  
time-out or by executing the ²CLR WDT² or ²HALT² in-  
struction. The PDF flag is affected only by executing the  
²HALT² or ²CLR WDT² instruction or during a system  
power-up.  
Program Counter Low Register - PCL  
To provide additional program control functions, the low  
byte of the Program Counter is made accessible to pro-  
grammers by locating it within the Special Purpose area  
of the Data Memory. By manipulating this register, direct  
jumps to other program locations are easily imple-  
mented. Loading a value directly into this PCL register  
will cause a jump to the specified Program Memory lo-  
cation, however, as the register is only 8-bit wide, only  
jumps within the current Program Memory page are per-  
mitted. When such operations are used, note that a  
dummy cycle will be inserted.  
The Z, OV, AC and C flags generally reflect the status of  
the latest operations.  
In addition, on entering an interrupt sequence or execut-  
ing a subroutine call, the status register will not be  
pushed onto the stack automatically. If the contents of  
the status registers are important and if the interrupt rou-  
tine can change the status register, precautions must be  
taken to correctly save it. Note that bits 0~3 of the  
STATUS register are both readable and writeable bits.  
Rev. 1.00  
23  