Table 1. SL353 Series Specifications
1
Characteristic
Supply voltage (Vs)
Active mode current
Sleep mode current
Average current:
SL353HT
SL353HT
SL353LT
SL353LT
Active mode time
Condition
Ta = -40 C to 85 C
Vs = 2.8 V, Ta = 25 °C
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
Vs = 2.8 V, Ta = 25 °C
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
Vs = 2.8 V, Ta = 25 °C
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
Vs = 2.8 V, Ta = 25 °C
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
Vs = 2.8 V, Ta = 25 °C
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
Min.
2.2
Typ.
2.8
2.5
2.5
1.5
1.5
0.33
0.33
1.8
1.8
6
6
Max.
5.5
4
9
2.5
8
0.64
2.3
3
9
9
30
Unit
V
mA
μA
mA
mA
μA
μA
μs
3
3
Period:
SL353HT
Vs = 2.8 V, Ta = 25 °C
30
45
80
μs
SL353HT
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
20
45
150
μs
SL353LT
Vs = 2.8 V, Ta = 25 °C
30
45
80
ms
SLS353LT
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
20
45
150
ms
Duty cycle:
SL353HT
Vs = 2.8 V, Ta = 25 °C
10
13
16
SL353HT
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
5
13
25
%
SL353LT
Vs = 2.8 V, Ta = 25 °C
0.01
0.013
0.016
SL353LT
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
0.005
0.013
0.025
1
Vout :
high
Vs = 2.8 V, Ta = 25 °C, load current = 100 µA
Vs - 0.15 Vs - 0.11
high
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C, load current = 100 µA Vs - 0.25 Vs - 0.11
V
low
Vs = 2.8 V, Ta = 25 °C, load current = 100 µA
0.11
0.15
low
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C, load current = 100 µA
0.11
0.25
Operate point (positive)
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
20
60
110
Gauss
Operate point (negative)
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
-110
-60
-20
Gauss
Release point (positive)
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
5
45
95
Gauss
Release point (negative)
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
-95
-45
-5
Gauss
Differential
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
3
15
60
Gauss
Operating temperature
Vs = 2.2 V to 5.5 V, Ta = -40 C to 85 C
-40 [-40]
85 [185] °C [°F]
Storage temperature
-40 [-40]
150 [302] °C [°F]
Note 1:
These Hall-effect sensors may have an initial output in either the ON or OFF state if powered up with an applied magnetic
field in the differential zone (applied magnetic field > Brp and < Bop). Honeywell recommends that the application circuit designer
allow 10 µs after supply voltage has reached its rated value for the output voltage to stabilize.
Table 2. SL353 Series Absolute Maximum Ratings
1
Characteristic
Condition
Min.
Typ.
Max.
Unit
Supply voltage
-0.5
6
V
Operating temperature
ambient
-40 [-40]
150 [302]
C [°F]
Soldering temperature
applied for <10 s
265 [509]
C [°F]
Output (load) current
5
mA
Note 1:
The magnetic field strength (Gauss) required to cause the sensor to change state (operate and release) will be as
specified in the magnetic characteristics. To test the sensor against the specified magnetic characteristics, the sensor must be
placed in a uniform magnetic field.