NOTICE
Absolute maximum ratings are the extreme limits that the device will withstand without
damage to the device. However, the electrical and mechanical characteristics are not
guaranteed as the maximum limits (above recommended operating conditions) are
approached, nor will the device necessarily operate at absolute maximum ratings.
Figure 2. SL353HT and SL353LT Typical Magnetic
Figure 1. SL353 Series Block/Electrical Diagram
Performance vs Temp.
Magnetic Switch Point (Gauss)
100
80
60
40
20
0
-20
-40
-60
-80
-100
-40
Release Point (Neg.)
-20
0
20
40
Temperature (°C)
60
80
Operate Point (Neg.)
Operate Point (Pos.)
Release Point (Pos.)
Figure 3. SL353HT and SL353LT Typical Period vs Temp.
Period
(µs for SL353HT, ms for SL353LT)
120
100
80
60
40
Vs = 5.5 V
20
0
-40
Vs = 2.8 V
Vs = 2.2 V
Figure 4. SL353HT and SL353LT Typical Active Mode Time
vs Temp.
20
18
16
14
12
10
8
6
4
2
0
-40
Vs = 5.5 V
Vs = 2.8 V
Active Mode Time (µs)
Vs = 2.2 V
-20
0
20
40
Temperature (°C)
60
80
-20
0
20
40
Temperature (°C)
60
80
Figure 5. SL353HT Typical Average Current vs Temp.
1
0.9
Vs = 5.5 V
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
-40
-20
0
20
40
Temperature (°C)
60
80
Vs = 2.2 V
Vs = 2.8 V
Figure 6. SL353LT Typical Average Current vs Temp.
8
7
Vs = 5.5 V
Average Current (mA)
Average Current (µA)
6
5
4
3
2
1
0
-40
-20
0
20
40
Temperature (°C)
Vs = 2.8 V
Vs = 2.2 V
60
80
4
www.honeywell.com/sensing