5
IEC/EN/DIN EN 60747-5-2
Insulation Characteristics
Description
Symbol HCPL-3150#060
Installation classification per DIN VDE
0110/1.89, Table 1
for rated mains voltage
≤
150 Vrms
for rated mains voltage
≤
300 Vrms
I-IV
for rated mains voltage
≤
600 Vrms
I-III
Climatic Classification
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
V
IORM
630
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production
Test with t
m
= 1 sec,
V
PR
1181
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and Sample
Test, t
m
= 60 sec,
V
PR
945
Partial discharge < 5 pC
Highest Allowable Overvoltage*
V
IOTM
6000
(Transient Overvoltage t
ini
= 10 sec)
Safety-Limiting Values – Maximum Values
Allowed in the Event of a Failure, Also
See Figure 37, Thermal Derating Curve.
Case Temperature
T
S
175
Input Current
I
S, INPUT
230
Output Power
P
S, OUTPUT
600
Insulation Resistance at T
S
, V
IO
= 500 V
R
S
≥
10
9
HCPL-315J**
Unit
I-IV
I-III
I-II
55/100/21
2
891
Vpeak
1670
Vpeak
1336
6000
Vpeak
Vpeak
175
400
1200
≥
10
9
°C
mA
mW
Ω
**Approval Pending.
*Refer to the front of the optocoupler section of the current Catalog, under Product Safety Regulations section IEC/EN/DIN EN
60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
Note:
Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits
in application.