Switching Specifications (AC)
Over recommended operating conditions (TA = -40 to 100°C, IF(ON) = 7 to 16 mA, VF(OFF) = -3.0 to 0.8 V,
VCC = 15 to 30 V, VEE = Ground) unless otherwise specified.
Parameter
Symbol
Min.
Typ.* Max. Units
Test Conditions
Fig.
Note
Propagation Delay
Time to High
Output Level
tPLH
0.10
0.30
0.50
µs
Rg = 47 Ω,
Cg = 3 nF,
f = 10 kHz,
10, 11,
12, 13
14, 23
14
Duty Cycle = 50%
Propagation Delay
Time to Low
tPHL
0.10
0.27
0.50
µs
Output Level
Pulse Width
Distortion
Propagation Delay
PWD
PDD
0.3
µs
µs
15
10
-0.35
0.35
34,35
Difference Between (tPHL - tPLH
Any Two Parts
)
Rise Time
Fall Time
UVLO Turn On
Delay
tr
tf
0.1
0.1
0.8
µs
µs
µs
23
22
tUVLO ON
VO > 5 V,
IF = 10 mA
UVLO Turn Off
Delay
Output High Level
Common Mode
Transient
tUVLO OFF
|CMH|
0.6
30
µs
VO < 5 V,
IF = 10 mA
15
15
kV/µs TA = 25°C,
IF = 10 to 16 mA,
24
11, 12
11, 13
VCM = 1500 V,
VCC = 30 V
Immunity
Output Low Level
Common Mode
Transient
|CML|
30
kV/µs TA = 25°C,
VCM = 1500 V,
VF = 0 V,
Immunity
VCC = 30 V
Package Characteristics
Parameter
Symbol
Min.
Typ.* Max. Units
Test Conditions
Fig.
Note
Input-Output
V
ISO
2500
Vrms RH < 50%,
8, 9
Momentary
t = 1 min.,
Withstand Voltage**
Resistance
(Input - Output)
Capacitance
(Input - Output)
LED-to-Case
Thermal Resistance
LED-to-Detector
TA = 25°C
RI-O
CI-O
θLC
θLD
θDC
1012
0.6
Ω
VI-O = 500 VDC
9
pF
f = 1 MHz
391
439
119
°C/W Thermocouple
28
located at center
underside of
package
°C/W
°C/W
Thermal Resistance
Detector-to-Case
Thermal Resistance
*All typical values at TA = 25°C and VCC - VEE = 30 V, unless otherwise noted.
**The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to your equipment level safety specification or HP Application Note
1074 entitled “Optocoupler Input-Output Endurance Voltage.”
1-202