GM71VS18163CL
Read Cycle
Symbol
Parameter
Access Time from RAS
Access Time from CAS
Access Time from Address
Access Time from OE
Read Command Setup Time
Read Command Hold Time to CAS
Read Command Hold Time to RAS
Column Address to RAS Lead Time
Column Address to CAS Lead Time
CAS to Output in Low-Z
Output Data Hold Time
Output Data Hold Time from OE
Output Buffer Turn-off Time
Output Buffer Turn-off Time to OE
CAS to D
IN
Delay Time
Read Command Hold Time from RAS
Output Data hold Time from RAS
Output Buffer turn off to RAS
Output Buffer turn off to WE
WE to D
IN
Delay Time
RAS to D
IN
Delay Time
GM71V(S)18163 GM71V(S)18163 GM71V(S)18163
C/CL-5
C/CL-6
C/CL-7
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Note
8,9
9,10,17
9,11,17
Min Max
Min Max Min Max
-
-
-
-
0
0
5
30
18
0
3
3
-
-
15
60
3
-
-
15
15
60
15
30
15
-
-
-
-
-
-
-
-
15
15
-
-
-
15
15
-
-
-
-
-
-
0
0
5
35
23
0
3
3
-
-
18
70
3
-
-
18
18
70
18
35
18
-
-
-
-
-
-
-
-
15
15
-
-
-
15
15
-
-
t
RAC
t
CAC
t
AA
t
OAC
t
RCS
t
RCH
t
RRH
t
RAL
t
CAL
t
CLZ
t
OH
t
OHO
t
OFF
t
OEZ
t
CDD
t
RCHR
t
OHR
t
OFR
t
WEZ
t
WDD
t
RDD
-
-
-
-
0
0
5
25
15
0
3
3
-
-
13
50
3
-
-
13
13
50
13
25
13
-
-
-
-
-
-
-
-
13
13
-
-
-
13
13
-
-
9
21
12,22
12
27
13,27
13
5
27
27
Rev 0.1 / Apr’01