iC-NQC
preliminar y
Rev B1, Page 9/29
13-bit Sin/D CONVERTER WITH SIGNAL CALIBRATION
OPERATING REQUIREMENTS: I/O Interface
Operating Conditions: VDD = 5 V ±10 %, Ta = -25 ... 85 °C; input levels lo = 0 ... 0.45 V, hi = 2.4 V ... VDD
Item
No.
Symbol
Parameter
Conditions
Fig.
Min.
Permissible Clock Period
Clock Signal Hi Level Duration
Clock Signal Lo Level Duration
Permissible Clock Period
Clock Signal Hi Level Duration
Clock Signal Lo Level Duration
t
tos
according to Table 35
t
tos
according to Table 45
4
4
4
5
5
5
250
25
25
100
25
25
Max.
2x t
tos
t
tos
t
tos
2x t
tos
t
tos
t
tos
ns
ns
ns
ns
ns
ns
Unit
SSI Protocol
I001 T
MAS
I002 t
MASh
I003 t
MASl
BiSS C Protocol
I004 T
MAS
I005 t
MASh
I006 t
MASl
Figure 3: Timing diagram in SSI protocol.
Figure 4: Timing diagram in BiSS C protocol.