X24165
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias
*
COMMENT
Stresses above those listed under “Absolute Maximum”
Ratings” may cause permanent damage to the device. This is
a stress rating only and the functional operation of the device
at these or any other conditions above those indicated in
the operational sections of this specification is not implied.
Exposure to absolute maximum rating conditions for
extended periods may
affect device reliability.
X24165 ....................................... –65°C to +135°C
Storage Temperature ........................ –65°C to +150°C
Voltage on any Pin with
Respect to V
SS
.................................... –1V to +7V
D.C. Output Current ..............................................5mA
Lead Temperature (Soldering, 10 Seconds) ...... 300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Military
Min.
0°C
–40°C
–55°C
Max.
+70°C
+85°C
+125°C
6551 FRM T04
Supply Voltage
X24165
X24165-2.7
Limits
4.5V to 5.5V
2.7V to 5.5V
6551 FRM T05
D.C. OPERATING CHARACTERISTICS
Limits
Symbol
I
CC1
I
CC2
I
SB1
(1)
Parameter
V
CC
Supply Current (Read)
V
CC
Supply Current (Write)
V
CC
Standby Current
Min.
Max.
1
3
50
Units
mA
mA
∝A
Test Conditions
SCL = V
CC
X 0.1/V
CC
X 0.9 Levels @
100KHz, SDA = Open, All Other
Inputs =
V
SS
or V
CC
– 0.3V
SCL = SDA = V
CC
, All Other
Inputs =
V
SS
or V
CC
– 0.3V,
V
CC
= 5V
±
10%
I
SB2
(1)
V
CC
Standby Current
1
∝A
SCL = SDA = V
CC
, All Other
Inputs =
V
SS
or V
CC
– 0.3V,
V
CC
= 2.7V
I
LI
I
LO
V
lL
(2)
V
IH
(2)
V
OL
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
–1
V
CC
x 0.7
10
10
V
CC
x 0.3
V
CC
+ 0.5
0.4
∝A
∝A
V
V
V
I
OL
= 3mA, V
CC
= 4.5V
6551 FRM T06.1
V
IN
=
V
SS
to V
CC
V
OUT
=
V
SS
to V
CC
CAPACITANCE
T
A
= +25°C, f = 1MHz, V
CC
= 5V
Symbol
C
I/O
(3)
C
IN
(3)
Parameter
Input/Output Capacitance (SDA)
Input Capacitance (S
1
,
S
2
, SCL)
Max.
8
6
Units
pF
pF
Test Conditions
V
I/O
= 0V
V
IN
= 0V
6551 FRM T07.1
Notes:
(1)Must perform a stop command prior to measurement.
(2)V
IL
min. and V
IH
max. are for reference only and are not 100% tested. (3)This
parameter is periodically sampled and not 100% tested.
11