X24C02
ABSOLUTE MAXIMUM RATINGS*
.................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
Temperature Under Bias
Voltage on any Pin with
................................ –1.0V to +7.0V
D.C. Output Current ............................................ 5 mA
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
Respect to V
SS
indicated in the operational sections of this specification is not
implied. Exposure to absolute maximum rating conditions
Lead Temperature (Soldering, 10 Seconds) ..... 300°C
for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Supply Voltage
Limits
Temperature
Min.
Max.
X24C02
4.5V to 5.5V
3.5V to 5.5V
3V to 5.5V
2.7 to 5.5V
Commercial
Industrial
Military
0°C
70°C
+85°C
+125°C
X24C02-3.5
X24C02-3
X24C02-2.7
–40°C
–55°C
3838 PGM T09
3838 PGM T10
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified).
Limits
Symbol
Parameter
Min.
Max.
Units
Test Conditions
l
Power Supply Current (read)
1
mA
CC1
SCL = VCC x 0.1/VCC x 0.9 Levels @ 100
KHz, SDA = Open, All Other
Inputs = GND or V – 0.3V
l
Power Supply Current (write)
Standby Current
2
CC2
CC
(1)
∝A
∝A
SCL = SDA = VCC – 0.3V, All other
Inputs = GND or VCC, VCC = 5.5V
SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC = 3.3V + 10%
ISB
50
(2)
ISB
Standby Current
30
∝A
∝A
I
V
= GND to V
IN CC
Input Leakage Current
Output Leakage Current
Input Low Voltage
10
10
LI
I
LO
VOUT = GND to VCC
(2)
V
x 0.3
VlL
–1.0
V
V
V
CC
(2)
V
x 0.7V + 0.5
CC
VIH
Input High Voltage
CC
V
I
OL
= 3 mA
Output Low Voltage
0.4
OL
3838 PGM T02
CAPACITANCE TA = 25°C, f = 1 MHz, VCC = 5V
Symbol
Parameter
Max.
Units
Test Conditions
(3)
V
V
= 0V
CI/O
Input/Output Capacitance (SDA)
8
6
pF
pF
I/O
(3)
Input Capacitance (A , A , A , SCL, WC)
2
= 0V
CIN
0
1
IN
3838 PGM T04
Notes:(1)Must perform a stop command prior to measurement.
(2)VIL min. and VIH max. are for reference only and are not tested. (3)This
parameter is periodically sampled and not 100% tested.
9