ICS501
LOCO™PLL Clock Multiplier
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS501. These ratings, which
are standard values for ICS commercially rated parts, are stress ratings only. Functional operation of the
device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Item
Rating
Supply Voltage, VDD
All Inputs and Outputs
7 V
-0.5 V to VDD+0.5 V
-40 to +85°C
-65 to +150°C
260°C
Ambient Operating Temperature
Storage Temperature
Soldering Temperature
Recommended Operation Conditions
Parameter
Min.
Typ.
Max.
+70
Units
°C
Ambient Operating Temperature
Power Supply Voltage (measured in respect to GND)
0
+3.0
+5.5
V
DC Electrical Characteristics
VDD=5.0 V 5% , Ambient temperature 0 to +70°C, unless stated otherwise
Parameter
Symbol Conditions
Min.
3.0
Typ.
Max.
Units
Operating Voltage
VDD
5.5
(VDD/2)-1
0.8
V
V
Input High Voltage, ICLK only
Input Low Voltage, ICLK only
Input High Voltage
V
ICLK (pin 1)
ICLK (pin 1)
OE (pin 7)
OE (pin 7)
S0, S1
(VDD/2)+1
IH
V
V
IL
V
2.0
VDD-0.5
2.4
V
IH
Input Low Voltage
V
V
IL
Input High Voltage
V
V
IH
Input Low Voltage
V
S0, S1
0.5
V
IL
Output High Voltage
V
I
I
= -25 mA
= 25 mA
V
OH
OH
OL
Output Low Voltage
V
0.4
V
OL
IDD Operating Supply Current, 20
Short Circuit Current
No load, 100M
CLK output
20
mA
mA
+70
MDS 501 K
4
Revision 071304