IC62LV256L
OPERATING RANGE
Range
Commercial
Industrial
Ambient Temperature
0°C to +70°C
–40°C to +85°C
V
CC
3.3V +10%
3.3V
±
10%
DC ELECTRICAL CHARACTERISTICS
(Over Operating Range)
Symbol
V
OH
V
OL
V
IH
V
IL
I
LI
I
LO
Parameter
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
(1)
Input Leakage
Output Leakage
GND
≤
V
IN
≤
V
CC
GND
≤
V
OUT
≤
V
CC
, Outputs Disabled
Com.
Ind.
Com.
Ind.
Test Conditions
V
CC
= Min., I
OH
= –2.0 mA
V
CC
= Min., I
OL
= 4.0 mA
Min.
2.4
—
2.2
–0.3
–2
–5
–2
–5
Max.
—
0.4
V
CC
+ 0.3
0.8
2
5
2
5
Unit
V
V
V
V
µA
µA
Notes:
1. V
IL
= –3.0V for pulse width less than 10 ns.
2. Not more than one output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
POWER SUPPLY CHARACTERISTICS
(1)
(Over Operating Range)
Symbol Parameter
I
CC
1
I
CC
2
I
SB
1
Vcc Operating
Supply Current
Vcc Dynamic Operating
Supply Current
TTL Standby Current
(TTL Inputs)
CMOS Standby
Current (CMOS Inputs)
Test Conditions
V
CC
= Max.,
CE
= V
IL
I
OUT
= 0 mA, f = 0
V
CC
= Max.,
CE
= V
IL
I
OUT
= 0 mA, f = f
MAX
V
CC
= Max.,
V
IN
= V
IH
or V
IL
CE
≥
V
IH
, f = 0
V
CC
= Max.,
CE
≥
V
CC
– 0.2V,
V
IN
≥
V
CC
– 0.2V, or
V
IN
≤
0.2V, f = 0
Com.
Ind.
Com.
Ind.
Com.
Ind.
Com.
Ind.
-15 ns
Min. Max.
—
—
—
—
—
—
—
—
50
60
70
70
3
5
50
100
-20 ns
Min. Max.
—
—
—
—
—
—
—
—
50
60
60
60
3
5
50
100
-25 ns
Min. Max.
—
—
—
—
—
—
50
60
50
50
3
5
Unit
mA
mA
mA
I
SB
2
— 50
— 100
µA
Note:
1. At f = f
MAX
, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
CAPACITANCE
(1,2)
Symbol
C
IN
C
OUT
Parameter
Input Capacitance
Output Capacitance
Conditions
V
IN
= 0V
V
OUT
= 0V
Max.
6
5
Unit
pF
pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: T
A
= 25°C, f = 1 MHz, Vcc = 3.3V.
4
Integrated Circuit Solution Inc.
ALSR008-0A 10/5/2001