IS61S6432
WRITE CYCLE SWITCHING CHARACTERISTICS
(Over Operating Range)
Symbol
t
KC
t
KH
t
KL
t
AS
t
SS
t
WS
t
DS
t
CES
t
AVS
t
AH
t
SH
t
DH
t
WH
t
CEH
t
AVH
t
CFG
(2)
Parameter
Cycle Time
Clock High Time
Clock Low Time
Address Setup Time
Address Status Setup Time
Write Setup Time
Data In Setup Time
Chip Enable Setup Time
Address Advance Setup Time
Address Hold Time
Address Status Hold Time
Data In Hold Time
Write Hold Time
Chip Enable Hold Time
Address Advance Hold Time
Configuration Setup
-200
(1)
Min. Max.
5
1.6
1.6
2
2
2
2
2
2
0.5
0.5
0.5
0.5
0.5
0.5
25
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
-166
Min. Max.
6
2.4
2.4
2.5
2.5
2.5
2.5
2.5
2.5
0.5
0.5
0.5
0.5
0.5
0.5
25
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
-133
-117
Min. Max. Min. Max.
7.5
2.8
2.8
2.5
2.5
2.5
2.5
2.5
2.5
0.5
0.5
0.5
0.5
0.5
0.5
30
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
8.5
3
3
2.5
2.5
2.5
2.5
2.5
2.5
0.5
0.5
0.5
0.5
0.5
0.5
35
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Symbol
t
KC
t
KH
t
KL
t
AS
t
SS
t
WS
t
DS
t
CES
t
AVS
t
AH
t
SH
t
DH
t
WH
t
CEH
t
AVH
t
CFG
(2)
Parameter
Cycle Time
Clock High Time
Clock Low Time
Address Setup Time
Address Status Setup Time
Write Setup Time
Data In Setup Time
Chip Enable Setup Time
Address Advance Setup Time
Address Hold Time
Address Status Hold Time
Data In Hold Time
Write Hold Time
Chip Enable Hold Time
Address Advance Hold Time
Configuration Setup
-5
Min. Max.
10
3.5
3.5
2.5
2.5
2.5
2.5
2.5
2.5
0.5
0.5
0.5
0.5
0.5
0.5
35
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
-6
Min. Max.
12
4
4
2.5
2.5
2.5
2.5
2.5
2.5
0.5
0.5
0.5
0.5
0.5
0.5
45
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
-7
-8
Min. Max. Min. Max.
13
6
6
2.5
2.5
2.5
2.5
2.5
2.5
0.5
0.5
0.5
0.5
0.5
0.5
52
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
15
6
6
2.5
2.5
2.5
2.5
2.5
2.5
0.5
0.5
0.5
0.5
0.5
0.5
60
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Note:
1.
ADVANCE INFORMATION ONLY.
2. Configuration signal MODE is static and must not change during normal operation.
Integrated Circuit Solution Inc.
SSE003-0B
11