IS61S6432
CAPACITANCE
(1,2)
Symbol
C
IN
C
OUT
Parameter
Input Capacitance
Input/Output Capacitance
Conditions
V
IN
= 0V
V
OUT
= 0V
Max.
6
8
Unit
pF
pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: T
A
= 25°C, f = 1 MHz, Vcc = 3.3V.
AC TEST CONDITIONS
Parameter
Input Pulse Level
Input Rise and Fall Times
Input and Output Timing
and Reference Level
Output Load
Unit
0V to 3.0V
1.5 ns
1.5V
See Figures 1 and 2
AC TEST LOADS
317
Ω
3.3V
Z
O
= 50Ω
OUTPUT
Output
Buffer
30 pF
50Ω
5 pF
Including
jig and
scope
351
Ω
1.5V
Figure 1
Figure 2
Integrated Circuit Solution Inc.
SSE003-0B
7