IDT54/74FCT16244T/AT/CT/ET, 162244T/AT/CT/ET,
166244T/AT/CT, 162H244T/AT/CT/ET FAST CMOS 16-BIT BUFFER/LINE DRIVER
MILITARY AND COMMERCIAL TEMPERATURE RANGES
ABSOLUTE MAXIMUM RATINGS
(1)
Symbol
Description
Max.
V
TERM(2)
Terminal Voltage with Respect to –0.5 to +7.0
GND
(3)
Terminal Voltage with Respect to
V
TERM
–0.5 to
GND
V
CC
+0.5
T
STG
Storage Temperature
–65 to +150
I
OUT
DC Output Current
–60 to +120
Unit
V
V
°C
mA
FUNCTION TABLE
(1)
Inputs
x
OE
L
L
H
NOTE:
1. H = HIGH Voltage Level
X = Don’t Care
L = LOW Voltage Level
Z = High Impedance
xAx
L
H
X
Outputs
xYx
L
H
Z
2544 tbl 02
2544 lnk 03
NOTES:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS
may cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating conditions for
extended periods may affect reliability.
2. All device terminals except FCT162XXXT and FCT166XXXT output and
I/O terminals.
3. Output and I/O terminals for FCT162XXXT and FCT166XXXT.
CAPACITANCE
(T
A
= +25°C, f = 1.0MHz)
Symbol
Parameter
(1)
C
IN
Input
Capacitance
C
OUT
Output
Capacitance
Conditions
V
IN
= 0V
V
OUT
= 0V
Typ.
3.5
3.5
Max. Unit
6.0
pF
8.0
pF
NOTE:
1. This parameter is measured at characterization but not tested.
2544 lnk 04
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE (STANDARD PARTS)
Following Conditions Apply Unless Otherwise Specified:
Commercial: T
A
= –40°C to +85°C, V
CC
= 5.0V
±
10%; Military: T
A
= –55°C to +125°C, V
CC
= 5.0V
±
10%
Symbol
V
IH
V
IL
I
I H
I
I L
I
OZH
I
OZL
V
IK
I
OS
V
H
I
CCL
I
CCH
I
CCZ
Parameter
Input HIGH Level
Input LOW Level
Input HIGH Current (Input pins)
(5)
Input HIGH Current (I/O pins)
(5)
Input LOW Current (Input pins)
(5)
Input LOW Current (I/O pins)
(5)
High Impedance Output Current
(3-State Output pins)
(5)
Clamp Diode Voltage
Short Circuit Current
Input Hysteresis
Quiescent Power Supply Current
V
CC
= Min., I
IN
= –18mA
V
CC
= Max., V
O
= GND
(3)
—
Test Conditions
(1)
Guaranteed Logic HIGH Level
Guaranteed Logic LOW Level
V
CC
= Max.
V
I
= V
CC
V
I
= GND
V
CC
= Max.
V
O
= 2.7V
V
O
= 0.5V
Min.
2.0
—
—
—
—
—
—
—
—
–80
—
—
Typ.
(2)
—
—
—
—
—
—
—
—
–
0.7
–
140
Max.
—
Unit
V
V
µA
0.8
±1
±1
±1
±1
±1
±1
–
1.2
–
225
—
µA
V
mA
mV
µA
100
5
V
CC
= Max., V
IN
= GND or V
CC
500
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at Vcc = 5.0V, +25°C ambient.
3. Not more than one output should be tested at one time. Duration of the test should not exceed one second.
4. Duration of the condition can not exceed one second.
5. The test limit for this parameter is
±
5µA at T
A
= –55°C.
2544 lnk 05
5.2
3