IDT79R3051/79R3052 INTEGRATED RISControllers
COMMERCIAL TEMPERATURE RANGE
ABSOLUTE MAXIMUM RATINGS
(1, 3)
Symbol
V
TERM
Rating
Terminal Voltage
with Respect
to GND
Operating Case
Temperature
Temperature
Under Bias
Storage
Temperature
Input Voltage
Commercial
–0.5 to +7.0
Unit
V
RECOMMENDED OPERATING
TEMPERATURE AND SUPPLY VOLTAGE
Grade
Commercial
Temperature
0°C to +85°C
(Case)
GND
0V
V
CC
5.0
±5%
2874 tbl 06
T
C
T
BIAS
T
STG
V
IN
0 to +85
–55 to +125
–55 to +125
–0.5 to +7.0
°C
°C
°C
V
OUTPUT LOADING FOR AC TESTING
+4mA
NOTES:
2874 tbl 04
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS
may cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification is not
implied. Exposure to absolute maximum rating conditions for extended
periods may affect reliability.
2. V
IN
minimum = –3.0V for pulse width less than 15ns.
V
IN
should not exceed V
CC
+0.5V.
3. Not more than one output should be shorted at a time. Duration of the short
should not exceed 30 seconds.
V
REF
+1.5V
–
+
To Device
Under Test
25pF
–4mA
2874 drw 08
AC TEST CONDITIONS
Symbol
V
IH
V
IL
V
IHS
V
ILS
Parameter
Input HIGH Voltage
Input LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Min.
3.0
—
3.5
—
Max.
—
0
—
0
Unit
V
V
V
V
2874 tbl 05
DC ELECTRICAL CHARACTERISTICS
(T
C
= 0°C to +85°C, V
CC
= +5.0V
±5%)
20MHz
Symbol
V
OH
V
OL
V
IH
V
IL
V
IHS
V
ILS
C
IN
C
OUT
I
CC
I
IH
I
IL
I
OZ
Parameter
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
(3)
Input LOW Voltage
(1)
Input HIGH Voltage
(2,3)
Input LOW Voltage
(1,2)
Input Capacitance
(4)
Output Capacitance
(4)
Operating Current
Input HIGH Leakage
Input LOW Leakage
Output Tri-state Leakage
Test Conditions
V
CC
= Min., I
OH
= –4mA
V
CC
= Min., I
OL
= 4mA
—
—
—
—
—
—
V
CC
= 5V, T
C
= 25°C
V
IH
= V
CC
V
IL
= GND
V
OH
= 2.4V, V
OL
= 0.5V
Min.
3.5
—
2.0
—
3.0
—
—
—
—
—
–100
–100
Max.
—
0.4
—
0.8
—
0.4
10
10
350
100
—
100
25MHz
Min.
3.5
—
2.0
—
3.0
—
—
—
—
—
–100
–100
Max.
—
0.4
—
0.8
—
0.4
10
10
400
100
—
100
33.33MHz
Min.
3.5
—
2.0
—
3.0
—
—
—
—
—
–100
–100
Max.
—
0.4
—
0.8
—
0.4
10
10
450
100
—
100
40MHz
Min.
3.5
—
2.0
—
3.0
—
—
—
—
—
–100
–100
Max. Unit
—
0.4
—
0.8
—
0.4
10
10
500
100
—
100
V
V
V
V
V
V
pF
pF
mA
µA
µA
µA
2874 tbl 07
NOTES:
1. V
IL
Min. = –3.0V for pulse width less than 15ns. V
IL
should not fall below –0.5V for larger periods.
2. V
IHS
and V
ILS
apply to CIk2xIn and
Reset
.
3. V
IH
should not be held above V
CC
+ 0.5V.
4. Guaranteed by design.
5.3
11