MHP270 SERIES
65 WATT
ABSOLUTE MAXIMUM RATINGS
Input Voltage
• 160 to 400 VDC
Output Power
• 50 to 65 watts depending on model
Lead Soldering Temperature (10 sec)
• 300°C
Storage Temperature Range (Case)
• –65°C to +150°C
DC/DC C
ONVERTERS
SYNC AND INHIBIT (INH1, INH2)
Sync In (525 to 675 kHz)
• Duty cycle 40% min, 60% max
• Logic low 0.8 V max
• Logic high 4.5 V min
• If not used, connect to input common
• Referenced to input common
Sync Out - Referenced to input common
Inhibit (INH1, INH2) TTL Open Collector
• Logic low (output disabled)
INH1 referenced to input common
Logic low 0.8 V max
INH2 referenced to output common
Logic low 0.5 V max
• Logic high (output enabled)
Open collector
TYPICAL CHARACTERISTICS
Output Voltage Temperature Coefficient
• 100 ppm/°C typical
Isolation
• 100 megohm minimum at 500 V
Conversion Frequency
• Free run mode 600 kHz typical
525 kHz. min., 675 kHz max
• External sync range: 525 to 675 kHz
Inhibit Pin Voltage (unit enabled)
• INH1 =12 V typ., INH2 = 5 V typ
Low Line Drop Out - Vout drops 50 mv
• Input voltage 155 VDC max
Undervoltage Lockout
• Input voltage 110 VDC min
Current Limit
• 125% of full load typical
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
• 160 to 400 VDC continuous
• 450 VDC for 50 msec transient
Case Operating Temperature (Tc)
• –55 to +100°C full power
PINS NOT IN USE
Inhibit (INH1, INH2)
Sync Out
Sync In
Share
Sense Lines
No connection
No connection
Connect to input common
Connect to output common
Must be connected to
appropriate outputs
Electrical Characteristics: 25°C Tc, 270 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
OUTPUT POWER
OUTPUT RIPPLE
VOLTAGE
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
INPUT CURRENT
10 kHz - 2 MHz
V
IN
= 160 TO 400 VDC
NO LOAD TO FULL
CONTINUOUS
TRANSIENT
1
50 ms
NO LOAD
INHIBITED - INH1
INHIBITED - INH2
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT
2
10 kHz - 10 MHz
POWER DISSIPATION
SHORT CIRCUIT
V
OUT
STEP LOAD RESP.
50% – 100% – 50%
TRANSIENT
RECOVERY
3
300
300
700
500
700
300
1800
1000
mV pk
µs
160
76
270
50
50
50
400
450
20
8
15
50
19
1.5
160
81
270
50
120
120
400
450
20
10
15
50
19
1.5
160
80
270
75
150
150
400
450
20
7
15
45
19
1.0
160
80
270
280
280
280
400
450
20
10
15
50
23
1.0
mV p-p
mV
mV
VDC
V
mA
mA
CONDITION
V
IN
= 160 TO 400 VDC
V
IN
= 160 TO 400 VDC
MHP27005S
MIN
4.95
0
0
TYP MAX
5.00 5.05
10
50
MHP27012S
MIN TYP MAX
11.88 12.00 12.12
0
0
5
60
MHP27015S
MIN TYP MAX
14.85 15.00 15.15
0
0
4.33
65
MHP27028S
MIN TYP MAX
27.22 28.00 28.28
0
0
2.32
65
UNITS
VDC
A
W
mA p-p
%
W
VDC
Notes
1. Unit will shut down above approximately 425V but will be undamaged
and will restart when voltage drops into normal range.
2. Indefinite short circuit protection not guaranteed above 100°C case.
3. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.