Cannon Trident Connectors
Connector Selection Guide
Flame
Snap Together
Rack and
Panel
Circular
Retardant
Neptune Metal
(TNM)
High Voltage
(THV)
Rectangular
Slimline
Rectangular
Multiway
Ringlock
Neptune
Up to
250 V ac rms
Up to 380 V ac
rms (7 position
connector only)
Operating
Voltage
Up to
250 V ac rms
Up to
Up to
Up to
250 V ac rms
Up to
250 V ac rms
Up to
500 V ac rms
*
1
250 V ac rms 250 V ac rms
Up to 13 A
Up to 13 A
Up to 13 A
Up to 16 A with
High Conductivity
Contacts
Up to 16 A
with High
Conductivity
Contacts
Current
Rating
Up to 16 A
with High
Conductivity
Contacts
Up to 34 A with
Power Contacts
Up to 13 A
Up to 10 A
Up to 13 A
Up to 13 A
2
Up to 30 A with
Power Contacts
Up to 30 A with
Power Contacts
Up to 40 A with
D Sub Contacts
-55°C to +125°C
(-67°F to +257°F)
(to +105°C,
221°F with
Plastic Hood)
-55°C to +105°C -55°C to +105°C
(-67°F to +221°F) (-67°F to +221°F)
-55°C to
+105°C
(-67°F to
+221°F)
-55°C to
+105°C
(-67°F to
+221°F)
-55°C to
+105°C
(-67°F to
+221°F)
-55°C to
+105°C
(-67°F to
+221°F)
-40°C to
+125°C
(-40°F to
+257°F)
Operating
Temperature
(from -40°C, -
40°F for
(from -40°C, -
40°F for
PCB versions)
PCB versions)
Insulation
Resistance
5000 MW at
500 V dc
5000 MW at
500 V dc
5000 MW at
500 V dc
5000 MW at
500 V dc
5000 MW at
500 V dc
5000 MW at
500 V dc
5000 MW at
500 V dc
5000 MW at
500 V dc
Up to 500
Up to 500
Up to 500
Up to 500
Up to 500
Up to 500
Up to 200
Mating Cycles
Up to 200
Mating Cycles
3
Durability
Mating Cycles Mating Cycles Mating Cycles Mating Cycles Mating Cycles Mating Cycles
Environmental
Sealing
-
-
-
-
Up to IP65
UL 94 V-0
Up to IP67
UL 94 V-0
Up to IP67
UL 94 V-0
Up to IP67
UL 94 V-0
I2/F2 according
to NFF 16-101
(fire & smoke
standards)
UL 94 V-0
Flammability
UL 94 V-0
UL 94 V-0
UL 94 V-1 with
Plastic Hoods
UL 94 V-0
Glass-Filled
Phenolic
Insulator
Black Nylon
-
Black Nylon
-
Grey PA
-
Black Nylon
Black Nylon
Black Nylon
Orange Nylon
Coupling
Ring
Nickel Plated
Copper Alloy
Nickel Plated
Copper Alloy
-
Nickel Plated Brass Nickel Plated Brass
4+0, 8+0, 12+0,
3+3, 4+3, 0+4,
19+0 **
12+0, 19+0
2, 3, 4, 6, 12,
24, 36
2, 3, 4, 6, 12, 14, 20, 26, 34, 4, 7, 8, 12, 19, 13+2, 20+4,
Layouts
Page
3, 4, 6, 9, 10
18-21
4
24, 36
50, 75
23, 28, 35, 48 28+4, 48+0,
19+12 **
7-13
14-17
22-25
26-35
36-51
52-60
61-62
* For details please consult the factory
** Signal + Power contacts
1 Depends on contacts used, layout, and degree of pollution
2 Depends on number and type of contacts used
3 Depends on plating and type of contacts used
www.ittcannon.com
6