Data Sheet
ESTW015A0F Series Eighth-Brick Power Modules
36–75Vdc Input; 3.3Vdc Output; 15A Output
August 20, 2010
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Device Symbol
Min
Typ
Max
Unit
Remote On/Off Signal Interface
(VIN=VIN, min to VIN, max ; open collector or equivalent,
Signal referenced to VIN- terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low - Remote On/Off Current (Von/off = -0.7 Vdc)
All
All
All
All
Ion/off
Von/off
Von/off
Ion/off
0.15
0.6
6.7
25
mA
Vdc
Vdc
μA
-0.7
2.4
Logic Low - On/Off Voltage
Logic High Voltage (Ion/off = 0Adc)
Logic High maximum leakage current
Turn-On Delay1 and Rise Times
(IO=IO, max , VIN=VIN, nom, TA = 25oC)
Case 1: Input power is applied for >1 second and then
the On/Off input is set to ON (Tdelay = time from instant
All
All
Tdelay
―
12
20
―
―
msec
msec
On/Off signal is ON until VO = 10% of VO, set
)
Case 2: On/Off input is set to Logic Low (Module
ON) and then input power is applied (Tdelay = time
Tdelay
―
―
at which VIN = VIN, min until Vo=10% of VO,set
Output voltage Rise time (time for Vo to rise from 10%
of Vo,set to 90% of Vo, set
)
All
All
Trise
4
―
msec
)
Output voltage overshoot – Startup
IO= IO, max; VIN=VIN, min to VIN, max, TA = 25 oC
Remote Sense Range
―
5
% VO, set
All
All
All
All
All
VSENSE
10
+10
5.0
% VO, set
% VO, set
Vdc
Output Voltage Adjustment Range
Output Overvoltage Protection (CO=220μF)
Overtemperature Protection – Hiccup Auto Restart
Input Undervoltage Lockout
Turn-on Threshold
-20
3.9
VO, limit
Tref
138
OC
VUVLO
32
30
2
34.5
Vdc
Vdc
Vdc
27.5
1
Turn-off Threshold
Hysteresis
1. The module has an adaptable extended Turn-On Delay interval, Tdelay, of 25mS. The extended Tdelay will occur when the module restarts following
either: 1) the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout (which causes module shutdown), and then back
to normal; or 2) toggling the on/off signal from on to off and back to on without removing the input voltage. The normal Turn-On Delay interval, Tdelay
will occur whenever a module restarts with input voltage removed from the module for the preceding 1 second.
,
LINEAGE POWER
4