欢迎访问ic37.com |
会员登录 免费注册
发布采购

QBK020A0B1 参数 Datasheet PDF下载

QBK020A0B1图片预览
型号: QBK020A0B1
PDF下载: 下载PDF文件 查看货源
内容描述: 36 - 55 VDC输入; 12VDC输出; 20A输出电流 [36 - 55 Vdc Input; 12Vdc Output; 20A Output Current]
分类和应用:
文件页数/大小: 16 页 / 494 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号QBK020A0B1的Datasheet PDF文件第4页浏览型号QBK020A0B1的Datasheet PDF文件第5页浏览型号QBK020A0B1的Datasheet PDF文件第6页浏览型号QBK020A0B1的Datasheet PDF文件第7页浏览型号QBK020A0B1的Datasheet PDF文件第9页浏览型号QBK020A0B1的Datasheet PDF文件第10页浏览型号QBK020A0B1的Datasheet PDF文件第11页浏览型号QBK020A0B1的Datasheet PDF文件第12页  
Data Sheet
March 27, 2008
QBK020A Series Power Modules; DC-DC Converters
36 – 55 Vdc Input; 12Vdc Output; 20A Output Current
Test Configurations
Design Considerations
Input Source Impedance
The power module should be connected to a low
ac-impedance source. A highly inductive source
impedance can affect the stability of the power module.
For the test configuration in Figure 9, a 100μF
electrolytic capacitor (ESR<0.7Ω at 100kHz), mounted
close to the power module helps ensure the stability of
the unit. Consult the factory for further application
guidelines.
Safety Considerations
Note: Measure input reflected-ripple current with a simulated
source inductance (LTEST) of 12 µH. Capacitor CS offsets
possible battery impedance. Measure current as shown above.
Figure 9. Input Reflected Ripple Current Test Setup.
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e., UL 1950, CSA C22.2 No. 60950-00, and VDE
0805:2001-12 (IEC60950 3
rd
Ed).
If the input source is non-SELV (ELV or a hazardous
voltage greater than 60 Vdc and less than or equal to
75Vdc), for the module’s output to be considered as
meeting the requirements for safety extra-low voltage
(SELV), all of the following must be true:
The input source is to be provided with reinforced
insulation from any other hazardous voltages,
including the ac mains.
One V
IN
pin and one V
OUT
pin are to be grounded, or
both the input and output pins are to be kept
floating.
Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum or
tantalum capacitor. Scope measurement should be made
using a BNC socket. Position the load between
51 mm and 76 mm (2 in. and 3 in.) from the module.
The input pins of the module are not operator
accessible.
Another SELV reliability test is conducted on the
whole system (combination of supply source and
subject module), as required by the safety agencies,
to verify that under a single fault, hazardous
voltages do not appear at the module’s output.
Note:
Do not ground either of the input pins of the
module without grounding one of the output pins.
This may allow a non-SELV voltage to appear
between the output pins and ground.
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
The input to these units is to be provided with a
maximum 15 A fast-acting (or time-delay) fuse in the
unearthed lead.
Figure 10. Output Ripple and Noise Test Setup.
CONT
ACT AND
DISTRIBUTION LOSSES
V
I
(+)
I
I
SUPPL
Y
V
I
(–)
CONT
ACT
RESIST
ANCE
V
O2
V
O1
I
O
LOAD
Note: All measurements are taken at the module terminals.
When socketing, place Kelvin connections at module terminals
to avoid measurement errors due to socket contact resistance.
Figure 11. Output Voltage and Efficiency Test Setup.
8
LINEAGE
POWER