Electrical Characteristics for LUXEON M at Test Current
[1]
,
Junction Temperature = 85°C for all CCTs and Royal Blue
Table 7.
Forward Voltage V
f [1, 2]
(V)
I
f
= 700 mA
Minimum
LXRx-Sxxx
LXRx-Rxxx
Notes for Table 7:
1. Test current is 700 mA for LXRx-Sxxx and 1400 mA for LXRx-Rxxx products.
2. Philips Lumileds maintains a tolerance of ± 0.5% on forward voltage measurements.
3. Measured between T
J
= 25°C and T
J
= 135°C.
10.5
5.44
Typical
11.2
5.6
Maximum
12
5.72
Typical Temperature Coefficient of
Forward Voltage
[3]
(mV/°C)
DV
F
/
DT
J
-5.5
-5.5
Typical Thermal Resistance Junction
to Thermal Pad
(°C/W)
Ru
J-C
1.25
1.25
Part Number
Absolute Maximum Ratings
Table 8.
Parameter
DC Forward Current (mA)
[1], [2]
Peak Pulsed Forward Current
[1], [3]
ESD Sensitivity
LED Junction Temperature
[1]
Operating Case Temperature at Current
Storage Temperature
Lead Soldering Temperature
Allowable Reflow Cycles
Autoclave Conditions
Reverse Voltage (V
r
)
Notes for Table 8:
1. Proper current derating must be observed to maintain junction temperature below the maximum.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple”, with frequencies ≥ 100Hz and
amplitude ≤ 1200 mA for LXRx-Sxxx and amplitude ≤ 2400 mA for LXRx-Rxxx are acceptable, assuming the average current throughout each cycle does not
exceed 1050 mA for LXRx-Sxxx and 2100 mA for LXRx-Rxxx.
3. Pulsed operation with a peak drive current of 1200 mA for LXRx-Sxxx and peak drive current of 2400 mA for LXRx-Rxxx is acceptable if the pulse on time
is ≤ 5ms per cycle and the duty cycle is ≤ 50%.
Maximum Performance
1050 mA for LXRx-Sxxx; 2100 mA for LXRx-Rxxx
1200 mA for LXRx-Sxxx; 2400 mA for LXRx-Rxxx
≤ 8000V Human Body Model (HBM)
Class 3B JESD22-A114-E
< 400V Machine Model (MM)
Class B JESD22-A115-B
135°C
-40°C - 120°C @ 700 mA for LXRx-Sxxx
-40°C - 120°C @1400 mA for LXRx-Rxxx
-40°C - 120°C
JEDEC 020c 260°C
3
121°C at 2 ATM
100% Relative Humidity for 96 Hours Maximum
LUXEON M LEDs are not designed to be driven in reverse bias
JEDEC Moisture Sensitivity
Table 9.
Level
Time
1
Unlimited
Soak Requirements
Floor Life
Conditions
[ 30°C / 85% RH
Time
168 Hrs. + 5 / -0 Hrs.
Standard
Conditions
85°C / 85% RH
7