IM Relay
Contact Data
Number of contacts and type
Contact assembly
Contact material
Limiting continuous current at max. ambient temperature
Maximum switching current
Maximum swichting voltage
Maximum switching capacity
Thermoelectric potential
Minimum switching voltage
Initial contact resistance / measuring condition: 10 mA / 20 mV
Electrical endurance at contact application 0
(£ 30 mV /
£
10 mA)
cable load open end
at 125Vdc / 0.24 A - 30 W
at 220 Vdc / 0.27 A - 60 W
at 250 Vac / 0.25 A - 62.5 VA
at 30 Vdc / 1 A - 30 W
at 30 Vdc / 2 A - 60 W
Mechanical endurance
UL contact ratings
2 changeover contacts
Bifurcated contacts
Palladium-ruthenium, gold-covered
2A
2A
220 Vdc
250 Vac
60 W, 62.5 VA
< 10
mV
100
mV
< 50 mW
min. 2.5 x 10
6
operations
min. 2.0 x 10
6
operations
min. 5 x 10
5
operations
min. 1 x 10
5
operations
min. 1 x 10
5
operations
min. 5 x 10
5
operations
min. 1 x 10
5
operations
typ. 10
8
operations
220 Vdc / 0.24 A - 60 W
125 Vdc / 0.24 A - 30 W
250 Vac / 0.25 A - 62.5 VA
125 Vac / 0.5 A - 62.5 VA
30 Vdc / 2 A - 60 W
Resistive load
Insulation resistance at 500 VDC
Dielectric test voltage (1 min)
between coil and contacts
between adjacent contact sets
between open contacts
Surge voltage resistance
according to Bellcore TR-NWT-001089 (2 / 10
ms)
between coil and contacts
between adjacent contact sets
between open contacts
according to FCC 68 (10 / 160
ms)
between coil and contacts
between adjacent contact sets
between open contacts
Insulation
Standard Version
> 10
9
W
1800 Vrms
1000 Vrms
1000 Vrms
High Dielectric Version
> 10
9
W
1800 Vrms
1800 Vrms
1500 Vrms
2500 V
1500 V
1500 V
2500 V
1500 V
1500 V
2500 V
2500 V
2500 V
2500 V
2500 V
2500 V
High Frequency Data
Capacitance
between coil and contacts
between adjacent contact sets
between open contacts
RF Characteristics
Isolation at 100 / 900 MHz
Insertion loss at 100 / 900 MHz
V.S.W.R. at 100 / 900 MHz
* High Dielectric Version „C“
- 37.0 dB / - 18.8 dB
- 0.03 dB / - 0.33 dB
1.06 / 1.49
max. 2 pF
max. 2 pF
max. 1 pF
Page 7 (12)
108-98001 Rev. D