欢迎访问ic37.com |
会员登录 免费注册
发布采购

705-5202-21 参数 Datasheet PDF下载

705-5202-21图片预览
型号: 705-5202-21
PDF下载: 下载PDF文件 查看货源
内容描述: Eclipse的?增强型705型导波雷达液位变送器 [Eclipse? Enhanced Model 705 Guided Wave Radar Level Transmitter]
分类和应用: 雷达
文件页数/大小: 28 页 / 1313 K
品牌: MAGNETROL [ MAGNETROL INTERNATIONAL, INC. ]
 浏览型号705-5202-21的Datasheet PDF文件第3页浏览型号705-5202-21的Datasheet PDF文件第4页浏览型号705-5202-21的Datasheet PDF文件第5页浏览型号705-5202-21的Datasheet PDF文件第6页浏览型号705-5202-21的Datasheet PDF文件第8页浏览型号705-5202-21的Datasheet PDF文件第9页浏览型号705-5202-21的Datasheet PDF文件第10页浏览型号705-5202-21的Datasheet PDF文件第11页  
T R A N S M I T T E R
P E R F O R M A N C E
Reference Conditions with a
72" coaxial type GWR probe
Œ
Linearity

Coaxial/twin
lead probes
Single lead
probes
Accuracy

Coaxial/twin
lead probes
Single lead
probes
7xT/7xL interface
Resolution
Repeatability
Hysteresis
Response Time
Warm-up Time
Ambient Temp.
S P E C I F I C A T I O N S
Reflection from liquid, with dielectric in center of
selected range, at 70 °F (+20 °C) with CFD threshold
< 0.1 % of probe length or 0.1" (2.5 mm),
whichever is greater
< 0.3 % of probe length or 0.3" (8 mm),
whichever is greater
< 0.1 % of probe length or 0.1" (2.5 mm),
whichever is greater
± 0.5 % of probe length or 0.5" (13 mm),
whichever is greater
± 1" (25 mm)
± 0.1" (2.5 mm)
< 0.1" (2.5 mm)
< 0.1" (2.5 mm)
< 1 second
< 5 seconds
-40° to +175° F (-40° to +80° C): blind transmitter
-5° to +160° F (-20° to +70° C): with digital display
-40° to +160° F (-40° to +70° C):
for EEx ia and EEx d[ia] with blind transmitter
-5° to +160° F (-20° to +70° C):
for EEx ia and EEx d[ia] with digital display
1200
1000
20.5 mA
800
630
600
400
200
24 VDC
0
0
10
11
20
VDC
30
40
GENERAL PURPOSE (GP)
INTRINSICALLY SAFE (IS)
EXPLOSION PROOF (XP)
Process Dielectric Effect
Operating Temp. Effect
Humidity
Electromagnetic Compatibility
Surge Protection
< 0.3" (7.5 mm) within selected range
Approx. +0.02 % of probe length/°C for probes
8' (2.5 m)
0-99 %, non-condensing
Meets CE requirements (EN-61326: 1997+A1+A2) and NAMUR NE 21
(Single and Twin Rod probe must be used in metallic vessel or stillwell)
Meets CE EN61326 (1000 V)
Œ
Specifications will degrade with Model 7xB, 7xD, and 7xP probes and/or Fixed threshold configuration.

Top 24 inches of Model 7xB probe: 1.2 inches (30 mm).
P R O B E
Description
Materials
S P E C I F I C A T I O N S
7xD / 7xL: High Pressure / High Temperature
GWR Probe
7xS: Saturated Steam GWR Probe
®
316/316L (1.4401/1.4404), Hastelloy C (2.4819) or Monel
®
(2.4360)
Borosilicate/Inconel X750
High Temp PEEK with Aegis PF 128
Alumina
(7xD-A, B and C)
– TFE
(7xD-W)
High Temp PEEK
High Temp PEEK
(7xD-V, N, P and R)
Inner rod 0.31" (8 mm) – outer tube 0.87" (22.5 mm)
Stainless steel:
Inner rod 0.63" (16 mm)
Outer tube 1.75" (45 mm)
n/a
Hastelloy C and Monel: Inner rod 0.63" (16 mm)
Outer tube 1.92" (49 mm)
Threaded:
3
4
" NPT or 1" BSP (G1) – except for enlarged probe
Flanged:
Various ANSI, DIN or “proprietary” mating flanges
From 24 to 240 inches (60 to 610 cm)
Œ
From 24 to 180 inches (60 to 450 cm)
None
8" (200 mm)
Ž
ε
r: 1.4 = 6" (150 mm) /
ε
r: 80 = 1" (25 mm)
ε
r
10 = 1" (25 mm)
+800° F @ 1500 psi (+430° C @ 103 bar)
+650° F @ 2250 psi (+345° C @ 155 bar)
+650° F @ 4700 psi (+345° C @ 324 bar) for
7xx-V, N, P and R
+400° F @ 5700 psi (+200° C @ 393 bar) for 7xx-W
-320° F @ 2000 psi (-196 °C @ 135 bar)
6250 psi @ +70° F (430 bar @ +20° C)
500 cP (standard) / 1500 cP (enlarged)
ε
r
1.4-100: 7xx-W, V, N, P and R
ε
r
2,0-100: 7xx-A, B and C
Full vacuum
(Helium leak < 10
-8
cc/s @ 1 atmosphere vacuum)
0° F @ 3000 psi (-15° C @ 205 bar)
2250 psi @ +650° F (155 bar @ +345° C)
500 cP
10 to 100
Negative pressure but not hermetic seal
Probe
Process seal
Spacers
Standard coax
Enlarged coax
Probe diameter
Process Connection
Probe length
Transition Zone
Max. Process
Temp.

Top
Bottom
Max
Min
Max. Process Pressure

Max. Viscosity
Dielectric Range
Vacuum service
Œ

Ž

Consult factory for insertion length < 24" (60 cm).
Transition Zone (zone with reduced accuracy) is dielectric dependent;
ε
r = dielectric permitivity. It is recommended to set 4–20 mA signal outside transition zones.
Consult factory for overfill applications.
7
See tables on page 9.